No index entries found.
Download This Guide
Related Documentation
- show chassis fpc
- show chassis fpc-feb-connectivity
- show chassis fabric fpcs
- Configuring the Junos OS to Make a Flexible PIC Concentrator Stay Offline
- Configuring the Junos OS to Resynchronize FPC Sequence Numbers with Active FPCs when an FPC Comes Online
- MX960 Flexible PIC Concentrator Description
request chassis fpc
List of Syntax
SyntaxSyntax (TX Matrix and TX Matrix Plus Routers)
Syntax (MX Series Routers)
Syntax (MX2020 3D Universal Edge Routers)
Syntax (MX2010 3D Universal Edge Routers)
Syntax (EX9200 Switches)
Syntax (QFabric System)
Syntax (PTX Series Packet Transport Routers)
Syntax
Syntax (TX Matrix and TX Matrix Plus Routers)
Syntax (MX Series Routers)
Syntax (MX2020 3D Universal Edge Routers)
Syntax (MX2010 3D Universal Edge Routers)
Syntax (EX9200 Switches)
Syntax (QFabric System)
Syntax (PTX Series Packet Transport Routers)
Release Information
Command introduced before Junos OS Release 7.4.
Command introduced in Junos OS Release 9.0 for EX Series switches.
Command introduced in Junos OS 11.3 for QFX Series.
Command introduced in Junos OS Release 12.1x48 for PTX Series Packet Transport Routers.
Command introduced in Junos OS Release 12.3 for MX2020 3D Universal Edge Routers.
Command introduced in Junos OS Release 12.3 for MX2010 3D Universal Edge Routers.
Command introduced in Junos OS Release 14.1X53-D20 for the OCX Series.
Command introduced in Junos OS Release 16.1R1 for the EX9200 switches.
Description
(M20, M40, M40e, M120, M160, M320, MX Series, and T Series routers, QFabric systems, EX Series switches, and PTX Series Packet Transport Routers only) Control the operation of the Flexible PIC Concentrator (FPC).
![]() | Note: Starting with Junos OS Release 12.3, it is possible that FPCs brought offline by using the request chassis fpc slot fpc-slot offline operational-mode CLI command can come online during a configuration commit or power-supply replacement procedure. As an alternative, use the set fpc fpc-slot power off configuration-mode command at the [edit chassis] hierarchy level to ensure that the FPCs remain offline. |
![]() | Note: In releases earlier than Junos OS Release 15.1F3 and Junos OS Release 16.1, offline FPCs in the PTX5000 router might be powered on by the router during a reboot, or when triggered by other power management events on the router, such as when you take another FPC offline. Starting with Junos OS Release 15.1F3 and Junos OS Release 16.1, offline FPCs do not come online during reboots or other power management events. To bring such an FPC online:
|
![]() | Note: If a CLI-based firmware upgrade is in progress, the specified FPC does not restart. Starting with Junos OS Release 15.1, the following message is displayed when this occurs: user@host> request chassis fpc slot 0 restart FPC 0 Firmware update in progress. Wait!!! |
![]() | Note: The command request chassis fpc (offline | online | restart) slot slot-number is not supported on PTX1000 router. |
Options
offline | — | Take the FPC offline. |
online | — | Bring the FPC online. |
interconnect-device name | — | (QFabric systems only) Bring the FPC on the QFX3008-I Interconnect device either offline or online:
|
restart | — | Restart the FPC. |
slot slot-number | — | FPC slot number:
|
all-members | — | (MX Series routers only) (Optional) Change FPC status of all members of the Virtual Chassis configuration. |
local | — | (MX Series routers only) (Optional) Change FPC status of the local Virtual Chassis member. |
member member-id | — | (MX Series routers only) (Optional) Change FPC status of the specified member of the Virtual Chassis configuration. Replace member-id with a value of 0 or 1. |
lcc number | — | (TX Matrix router and TX Matrix Plus router only) (Optional) Line-card chassis number. Replace number with the following values depending on the LCC configuration:
|
Required Privilege Level
maintenance
Related Documentation
- show chassis fpc
- show chassis fpc-feb-connectivity
- show chassis fabric fpcs
- Configuring the Junos OS to Make a Flexible PIC Concentrator Stay Offline
- Configuring the Junos OS to Resynchronize FPC Sequence Numbers with Active FPCs when an FPC Comes Online
- MX960 Flexible PIC Concentrator Description
List of Sample Output
request chassis fpcrequest chassis fpc (MX Series Routers with Media Services Blade [MSB])
request chassis fpc (MX2020 Router)
request chassis fpc (MX2010 Router)
request chassis fpc (EX9200 Switch)
Output Fields
When you enter this command, you are provided feedback on the status of your request.
Sample Output
request chassis fpc
user@host> request chassis fpc online slot 0
FPC 0 already online
request chassis fpc (MX Series Routers with Media Services Blade [MSB])
user@host> request chassis fpc slot 0
Possible completions: offline Take FPC offline online Bring FPC online restart Restart FPC
request chassis fpc (MX2020 Router)
user@host >request chassis fpc online slot 2
FPC 2 already online
request chassis fpc (MX2010 Router)
user@host >request chassis fpc offline slot 5
Offline initiated, use "show chassis fpc" to verify
request chassis fpc (EX9200 Switch)
user@host> request chassis fpc slot 0
Possible completions: offline Take FPC offline online Bring FPC online restart Restart FPC