Related Documentation

  • show chassis fpc
  • show chassis fpc-feb-connectivity
  • show chassis fabric fpcs
  • Configuring the Junos OS to Make a Flexible PIC Concentrator Stay Offline
  • Configuring the Junos OS to Resynchronize FPC Sequence Numbers with Active FPCs when an FPC Comes Online
  • MX960 Flexible PIC Concentrator Description

request chassis fpc

List of Syntax

Syntax
Syntax (TX Matrix and TX Matrix Plus Routers)
Syntax (MX Series Routers)
Syntax (MX2020 3D Universal Edge Routers)
Syntax (MX2010 3D Universal Edge Routers)
Syntax (EX9200 Switches)
Syntax (QFabric System)
Syntax (PTX Series Packet Transport Routers)

Syntax

request chassis fpc (offline | online | restart) slot slot-number

Syntax (TX Matrix and TX Matrix Plus Routers)

request chassis fpc (offline | online | restart) slot slot-number<lcc number>

Syntax (MX Series Routers)

request chassis fpc (offline | online | restart) slot slot-number<all-members><local><member member-id>

Syntax (MX2020 3D Universal Edge Routers)

request chassis fpc (offline | online | restart) slot slot-number

Syntax (MX2010 3D Universal Edge Routers)

request chassis fpc (offline | online | restart) slot slot-number

Syntax (EX9200 Switches)

request chassis fpc (offline | online | restart) slot slot-number

Syntax (QFabric System)

request chassis fpc<interconnect-device name slot slot-number (offline | online)><(offline | online) interconnect-device name slot slot-number><slot slot-number interconnect-device name (offline | online)>

Syntax (PTX Series Packet Transport Routers)

request chassis fpc (offline | online | restart) slot slot-number

Release Information

Command introduced before Junos OS Release 7.4.

Command introduced in Junos OS Release 9.0 for EX Series switches.

Command introduced in Junos OS 11.3 for QFX Series.

Command introduced in Junos OS Release 12.1x48 for PTX Series Packet Transport Routers.

Command introduced in Junos OS Release 12.3 for MX2020 3D Universal Edge Routers.

Command introduced in Junos OS Release 12.3 for MX2010 3D Universal Edge Routers.

Command introduced in Junos OS Release 14.1X53-D20 for the OCX Series.

Command introduced in Junos OS Release 16.1R1 for the EX9200 switches.

Description

(M20, M40, M40e, M120, M160, M320, MX Series, and T Series routers, QFabric systems, EX Series switches, and PTX Series Packet Transport Routers only) Control the operation of the Flexible PIC Concentrator (FPC).

Note: Starting with Junos OS Release 12.3, it is possible that FPCs brought offline by using the request chassis fpc slot fpc-slot offline operational-mode CLI command can come online during a configuration commit or power-supply replacement procedure. As an alternative, use the set fpc fpc-slot power off configuration-mode command at the [edit chassis] hierarchy level to ensure that the FPCs remain offline.

Note: In releases earlier than Junos OS Release 15.1F3 and Junos OS Release 16.1, offline FPCs in the PTX5000 router might be powered on by the router during a reboot, or when triggered by other power management events on the router, such as when you take another FPC offline.

Starting with Junos OS Release 15.1F3 and Junos OS Release 16.1, offline FPCs do not come online during reboots or other power management events. To bring such an FPC online:

  1. Delete the fpc fpc-slot power off statement from the [edit chassis] hierarchy level, if that statement is configured, and commit the configuration.
  2. Either issue the request chassis fpc online slot fpc-slot operational-mode CLI command or press and hold the FPC ONLINE/OFFLINE button for about 5 seconds until the green OK LED next to the button lights steadily.

Note: If a CLI-based firmware upgrade is in progress, the specified FPC does not restart. Starting with Junos OS Release 15.1, the following message is displayed when this occurs:

user@host> request chassis fpc slot 0 restart
FPC 0 Firmware update in progress. Wait!!!

Note: The command request chassis fpc (offline | online | restart) slot slot-number is not supported on PTX1000 router.

Options

offline

Take the FPC offline.

online

Bring the FPC online.

interconnect-device name

(QFabric systems only) Bring the FPC on the QFX3008-I Interconnect device either offline or online:

  • (QFabric System) On a QFabric system, specify the name of the QFX3008-I Interconnect device containing the FPC you want to bring either offline or online.
restart

Restart the FPC.

slot slot-number

FPC slot number:

  • M20 router—0 through 3.
  • M120 router—0 through 5.
  • MX240 router—0 through 2. On the MX240 router, slot-number corresponds to the (DPC slot number. If an MPC is installed, slot-number corresponds to the MPC slot number.
  • MX480 router—0 through 5. On the MX480 router, slot-number corresponds to the DPC slot number. If an MPC is installed, slot-number corresponds to the MPC slot number.
  • MX960 router—0 through 11. On the MX960 router, slot-number corresponds to the DPC slot number. If an MPC is installed, slot-number corresponds to the MPC slot number.
  • MX2020 router—0 through 19.
  • MX2010 router—0 through 9.
  • TX Matrix and TX Matrix Plus routers only—On the TX Matrix router, if you specify the number of the T640 router by using the lcc number option (the recommended method), replace slot-number with a value from 0 through 7. Otherwise, replace slot-number with a value from 0 through 31.

    Likewise, on a TX Matrix Plus router, if you specify the number of the T1600 or T4000 router by using the lcc number option (the recommended method), replace slot-number with a value from 0 through 7. Otherwise, replace slot-number with a value from 0 through 31. In case of TX Matrix Plus router with 3D SIBs, replace slot-number with a value from 0 through 63. For example, the following commands have the same result:

    user@host> request chassis fpc lcc 1 slot 1 offlineuser@host> request chassis fpc slot 9 offline
  • Other routers—0 through 7.
  • QFabric System—Replace slot-number with a value from 0 through 2.
  • EX Series switches:
    • EX4200 switches in a Virtual Chassis configuration—Replace slot-number with a value from 0 through 9.
    • EX6210 switches—Replace slot-number with a value from 0 through 9.

      Note: These commands are not supported for slots 4 and 5 when a Switch Fabric and Routing Engine (SRE) module is installed in those slots. These commands are supported for slots 4 and 5 only if a line card is installed in them.

    • EX8208 switches—Replace slot-number with a value from 0 through 7.
    • EX8216 switches—Replace slot-number with a value from 0 through 15.
    • EX9204 switches—Replace slot-number with a value from 0 through 2.
    • EX9208 switches—Replace slot-number with a value from 0 through 5.
    • EX9214 switches—Replace slot-number with a value from 0 through 11.
  • PTX5000 Packet Transport Router—Replace slot-number with a value from 0 through 7.
all-members

(MX Series routers only) (Optional) Change FPC status of all members of the Virtual Chassis configuration.

local

(MX Series routers only) (Optional) Change FPC status of the local Virtual Chassis member.

member member-id

(MX Series routers only) (Optional) Change FPC status of the specified member of the Virtual Chassis configuration. Replace member-id with a value of 0 or 1.

lcc number

(TX Matrix router and TX Matrix Plus router only) (Optional) Line-card chassis number.

Replace number with the following values depending on the LCC configuration:

  • 0 through 3, when T640 routers are connected to a TX Matrix router in a routing matrix.
  • 0 through 3, when T1600 routers are connected to a TX Matrix Plus router in a routing matrix.
  • 0 through 7, when T1600 routers are connected to a TX Matrix Plus router with 3D SIBs in a routing matrix.
  • 0, 2, 4, or 6, when T4000 routers are connected to a TX Matrix Plus router with 3D SIBs in a routing matrix.

Required Privilege Level

maintenance

Related Documentation

  • show chassis fpc
  • show chassis fpc-feb-connectivity
  • show chassis fabric fpcs
  • Configuring the Junos OS to Make a Flexible PIC Concentrator Stay Offline
  • Configuring the Junos OS to Resynchronize FPC Sequence Numbers with Active FPCs when an FPC Comes Online
  • MX960 Flexible PIC Concentrator Description

List of Sample Output

request chassis fpc
request chassis fpc (MX Series Routers with Media Services Blade [MSB])
request chassis fpc (MX2020 Router)
request chassis fpc (MX2010 Router)
request chassis fpc (EX9200 Switch)

Output Fields

When you enter this command, you are provided feedback on the status of your request.

Sample Output

request chassis fpc

user@host> request chassis fpc online slot 0
FPC 0 already online

request chassis fpc (MX Series Routers with Media Services Blade [MSB])

user@host> request chassis fpc slot 0
Possible completions:
  offline              Take FPC offline
  online               Bring FPC online
  restart              Restart FPC

request chassis fpc (MX2020 Router)

user@host >request chassis fpc online slot 2
FPC 2 already online

request chassis fpc (MX2010 Router)

user@host >request chassis fpc offline slot 5
Offline initiated, use "show chassis fpc" to verify

request chassis fpc (EX9200 Switch)

user@host> request chassis fpc slot 0
Possible completions:
  offline              Take FPC offline
  online               Bring FPC online
  restart              Restart FPC