Related Documentation

Identifying EX4300 Switch Models

Purpose

Identify the model number of your EX4300 switch.

Action

Check the value of the FRU Model Number field in the Routing Engine section in the output of the show chassis hardware extensive CLI command.

user@switch> show chassis hardware extensive

....
Routing Engine 1 REV D    650-044930   PD3113060024  EX4300-48P
 Jedec Code:   0x7fb0            EEPROM Version:    0x02
 P/N:          650-044930        S/N:               PD3113060024
 Assembly ID:  0x0b5e            Assembly Version:  03.19
 Date:         02-19-2013        Assembly Flags:    0x00
 Version:      REV D             CLEI Code:         
 ID: EX4300-48P                  FRU Model Number:  EX4300-48P
....

The model number of your switch is one of the following:

  • EX4300-24T
  • EX4300-24P
  • EX4300-32F
  • EX4300-32F-DC
  • EX4300-48T
  • EX4300-48T-AFI
  • EX4300-48T-DC
  • EX4300-48T-DC-AFI
  • EX4300-48P

In the sample output, the switch model is EX4300-48P.

Meaning

In EX4300 switch model numbers:

  • The 24T, 24P, 32F, 48T, and 48P in the model number indicate the type of network ports on the switch:
    • 24T—The switch has 24 10/100/1000BASE-T Ethernet network ports.
    • 24P—The switch has 24 10/100/1000BASE-T Ethernet network ports with all ports equipped for Power over Ethernet (PoE+).
    • 32F—The switch has 32 1-Gigabit SFP network ports.
    • 48T—The switch has 48 10/100/1000BASE-T Ethernet network ports.
    • 48P—The switch has 48 10/100/1000BASE-T Ethernet network ports with all ports equipped for PoE+.
  • AFI indicates that the switch is shipped with two fan modules and a power supply, each bearing an AIR IN (AFI) label. Switches that do not have AFI in their model numbers ship with two fan modules and a power supply, each bearing an AIR OUT (AFO) label.

    The labels on the fan modules and the power supplies indicate the direction of airflow they provide within the chassis when installed in the switch. AIR IN (AFI) labels indicate back-to-front airflow, and AIR OUT (AFO) labels indicate front-to-back airflow.

  • The DC in the model number indicates that the switch model works on DC power supply. Switches that do not have DC in their model numbers work on AC power supply.

Related Documentation