Download This Guide
Related Documentation
- See Rear Panel of an EX3300 Switch for port location.
- Connecting a Switch to a Network for Out-of-Band Management
Management Port Connector Pinout Information for an EX3300 Switch
The management port on an EX3300 switch uses an RJ-45 connector to connect to a management device for out-of-band management.
The port uses an autosensing RJ-45 connector to support a 10/100BASE-T connection. Two LEDs on the port indicate link/activity on the port and the administrative status of the port. See Management Port LEDs in EX3300 Switches.
Table 18 provides the pinout information for the RJ-45 connector for the management port. An Ethernet cable, with an RJ-45 connector attached, is supplied with the switch.
Table 18: Management Port Connector Pinout Information for EX3300 Switches
Pin | Signal | Description |
---|---|---|
1 | TRP1+ | Transmit/receive data pair 1 |
2 | TRP1- | Transmit/receive data pair 1 |
3 | TRP2+ | Transmit/receive data pair 2 |
4 | TRP3+ This pin is used only when the port is operating at 1000 Mbps. | Transmit/receive data pair 3 |
5 | TRP3- This pin is used only when the port is operating at 1000 Mbps. | Transmit/receive data pair 3 |
6 | TRP2- | Transmit/receive data pair 2 |
7 | TRP4+ This pin is used only when the port is operating at 1000 Mbps. | Transmit/receive data pair 4 |
8 | TRP4- This pin is used only when the port is operating at 1000 Mbps. | Transmit/receive data pair 4 |
Related Documentation
- See Rear Panel of an EX3300 Switch for port location.
- Connecting a Switch to a Network for Out-of-Band Management