timing source
Syntax
timing source selector { internal
| line lineType | uidType interfaceSpecifier }
Release Information
Command introduced before JunosE Release
7.1.0.
Description
Configures the router’s timing sources. Only
one of these timing sources can be an external source received through
an interface on an I/O module other than the SRP I/O module; the other
two must be either internal sources or external sources received through
the SRP I/O modules. There is no no version.
Options
- selector—Priority of the timing
source; in descending order: primary, secondary, or tertiary
- internal—Specifies the internal SC oscillator
- line—Specifies external timing input on the SRP
module
- lineType—One of the following
timing sources:
- e1:a—E1 clock, port A on SRP module
- e1:b—E1 clock, port B on SRP module
- t1:a—T1 clock, port A on SRP module
- t1:b—T1 clock, port B on SRP module
- uidType—One of the following
interfaces:
- ds1—Specifies a DS1 interface
- ds3—Specifies a DS3 interface
- e1—Specifies an E1 interface
- e3—Specifies an E3 interface
- sonet—Specifies a SONET interface
 | Note:
On the E120 and E320 routers, you can specify sonet for
only two of the available three timing sources (primary, secondary,
or tertiary). |
- interfaceSpecifier—Particular
interface; in the form slot/port[:subPort ]
Mode
Global Configuration
Published: 2012-06-29