Feature Explorer Login required New
 
File Format Help
 
Glossary
 
Portable Libraries
 
 
Home > Support > Technical Documentation > JunosE Software > ethernet oam lfm link-monitor frame-seconds-summary
Print
Rate and give feedback:  Feedback Received. Thank You!
Rate and give feedback: 
Close
This document helped resolve my issue.  Yes No

Additional Comments

800 characters remaining

May we contact you if necessary?

Name:  
E-mail: 
Submitting...
 

Related Documentation

  • ethernet oam lfm link-monitor symbol-period
  • ethernet oam lfm link-monitor frame-seconds
  • OAM Link Monitoring Feature
  • Configuring 802.3ah OAM Link-Fault Management
  • Example: Configuring 802.3ah OAM Link-Fault Management and Enabling Remote Failure Monitoring on an Interface
 

ethernet oam lfm link-monitor frame-seconds-summary

Syntax

ethernet oam lfm link-monitor frame-seconds-summary { threshold { high
{ highSummary | none } | low lowSummary } | window period }

no ethernet oam lfm link-monitor frame-seconds-summary [ threshold { high
{ highSummary | none } | low lowSummary } | window period ]

Release Information

Command introduced in JunosE Release 11.1.0.

Description

Configures a threshold value for frame period summary error events that triggers an action or causes an Errored Frame Seconds Summary Event TLV to be sent to the OAM entity, or a period of time in which frame period summary error events are counted. The no version disables monitoring of received frame period summary error events.

Note: You can configure this command multiple times to configure combinations of high and low threshold values or a window period for frame error events.

Options

  • link-monitor—Configures link monitoring parameters. Link monitoring operations start automatically when Ethernet OAM is enabled on an interface. When link monitoring operations are disabled, the interface does not actively send or receive Event Notification OAM PDUs
  • frame-seconds-summary—Configures the threshold value or window for frame period summary error events
  • threshold—Configures a period or a value at, above, or below which an action is triggered
  • highSummary—Integer in the range 1–65535 that is the high threshold in number of error frame seconds, which when exceeded causes an action to be triggered. The action that the local OAM entity performs when the high threshold value is exceeded depends on the value configured using the ethernet oam lfm high-threshold command. There is no default value. If you specify a high threshold option for frame period summary error events, you must also enter the number of frames, which when exceeded causes the configured action to be taken
  • none—Removes the high threshold value for frame period summary error events
  • lowSummary—Integer in the range 0–65535 that is the low threshold in number of error frame seconds, which when exceeded causes an Errored Frame Seconds Summary Event TLV to be sent to the peer; default value is 0 frames. If you do not configure a low threshold for framed symbol errors, the Link Fault critical event PDU is not sent to the peer
  • period—A window and period of time during which framed period summary seconds are counted. Integer in the range 10–900 seconds that is the monitoring period for framed symbol errors; default value is 60 seconds

Mode

Interface Configuration

 

Related Documentation

  • ethernet oam lfm link-monitor symbol-period
  • ethernet oam lfm link-monitor frame-seconds
  • OAM Link Monitoring Feature
  • Configuring 802.3ah OAM Link-Fault Management
  • Example: Configuring 802.3ah OAM Link-Fault Management and Enabling Remote Failure Monitoring on an Interface
 

Published: 2012-06-28

 
  • About Juniper
  • Investor Relations
  • Press Releases
  • Newsletters
  • Juniper Offices
  • Green Networking
  • Resources
  • How to Buy
  • Partner Locator
  • Image Library
  • Visio Templates
  • Security Center
  • Community
  • Forums
  • Blogs
  • Junos Central
  • Social Media
  • Developers
  • Support
  • Technical Documentation
  • Knowledge Base (KB)
  • Software Downloads
  • Product Licensing
  • Contact Support
Site Map / RSS Feeds / Careers / Accessibility / Feedback / Privacy & Policy / Legal Notices
Copyright© 1999-2012 Juniper Networks, Inc. All rights reserved.
Help
|
My Account
|
Log Out