Monitoring the Physical Environment of the Router
Purpose
Display information about the router’s physical environment, such as voltage or temperature. The system displays a message if the voltage or temperature exceeds normal operating limits. The system enters thermal protection mode if the temperature exceeds maximum operating limits or if the fan system on the E120 and E320 routers reports a critical error. For information about thermal protection mode on ERX7xx models, ERX14xx models, and the ERX310 router, see ERX Hardware Guide, Chapter 9, Troubleshooting. For information about thermal protection mode on the E120 and E320 routers, see E120 and E320 Hardware Guide, Chapter 9, Troubleshooting.
Optionally, you can specify the all keyword to view both the system environment information and the detailed temperature status table, or specify the table keyword to view only the temperature status table.
Action
To display the environment of an ERX7xx model:
host1#show environment all
chassis: 14 slot (id 0x3, rev. 0x0)
fabric: 5 Gbps (rev. 1)
fans: ok
nvs: ok (81MB flash disk, 54% full)
power: A ok, B not present
AC power: A not present, B not present
srp redundancy: none
*** slots: cards missing or offline
online: 6 9
standby: 8
offline: 2
empty: 0 1 3 4 5 7 10 11 12 13
line redundancy: 1 redundancy group(s)
width 6, spare 8, primary 9
temperature: ok
timing: primary
primary: internal SC oscillator (ok)
secondary: internal SC oscillator (ok)
tertiary: internal SC oscillator (ok)
auto-upgrade enabled
*** system operational: no processor processor IOA IOA
temperature temperature temperature temperature
slot (10C - 70C) status (10C - 70C) status
---- ----------- ----------- ----------- -----------
0 31 normal 30 normal
3 31 normal 30 normal
5 31 normal 30 normal
7 31 normal 30 normal
processor temperature ranges
below -5C is too cold
above 80C is too hot
low temperature warning below 10C
high temperature warning above 70C
IOA temperature ranges
below -5C is too cold
above 80C is too hot
low temperature warning below 10C
high temperature warning above 70CTo display the environment of an E320 router:
host1#show environment all
chassis: 17 slot (id 0x3, rev. 0x0)
fabric: 100 Gbps (rev. 1)
fans: fanSubsystemOk
nvs: ok (977MB flash disk, 29% full), matches running config
power: A ok, B not present
srp redundancy: mode is file-system-synchronization auto-sync
enabled, switch-on-error enabled
status unknown
*** slots: cards missing or offline
online: 0 6 13
offline: 7
empty: 1 2 3 4 5 11 12 14 15 16
fabric slots: ok
online: 6 7 8 9 10
line redundancy: none
temperature: ok
timing: primary
primary: internal SC oscillator (ok)
secondary: internal SC oscillator (ok)
tertiary: internal SC oscillator (ok)
auto-upgrade enabled
fabric redundancy: ok*** system operational: no
temperature temperature slot type (10C - 70C) status ---- ------------------ ----------- ----------- 0 LM-4 42 normal 0/1 GE-4 IOA 23 normal 6 SRP-100 32 normal 6 SFM-100 32 normal 6/0 SRP IOA 25 normal 7 SFM-100 30 normal 8 SFM-100 23 normal 9 SFM-100 25 normal 10 SFM-100 24 normal 13 LM-4 24 normal 13/0 GE-4 IOA 23 normal
fabric temperature ranges
below -5C is too cold
above 79C is too hot
low temperature warning below 10C
high temperature warning above 70C
processor temperature ranges
below -5C is too cold
above 79C is too hot
low temperature warning below 10C
high temperature warning above 70C
IOA temperature ranges
below -5C is too cold
above 79C is too hot
low temperature warning below 10C
high temperature warning above 70CTo display the environment on an E120 router:
host1#show environment all
chassis: 11 slot (id 0x8, rev. 0x0)
fabric: 120 Gbps (rev. 1)
fans: fanSubsystemOk
nvs: ok (998MB flash disk, 14% full), matches running config
power: A ok, B not present
srp redundancy: mode is file-system-synchronization auto-sync
enabled, switch-on-error enabled
in sync
slots: ok
online: 1 2 6
standby: 7
empty: 0 3 5
fabric slots: ok
online: 6 7 8 9 10
line redundancy: none
temperature: ok
timing: primary
primary: internal SC oscillator (ok)
secondary: internal SC oscillator (ok)
tertiary: internal SC oscillator (ok)
auto-upgrade enabled
fabric redundancy: oksystem operational: yes
temperature temperature slot type (10C - 56C) status ---- -------- ----------- ----------- 1 LM-10 37 normal 1/1 GE-8 IOA 35 normal 2 LM-10 37 normal 2/1 GE-8 IOA 39 normal 4 LM-10A-ADV 37 normal 6 SRP-120 40 normal 6 SFM-120 40 normal 6/0 SRP IOA 30 normal 7 SRP-120 41 normal 7 SFM-120 41 normal 8 SFM-120 31 normal 9 SFM-120 32 normal 10 SFM-120 32 normal
fabric temperature ranges
below -5C is too cold
above 79C is too hot
low temperature warning below 10C
high temperature warning above 56C
processor temperature ranges
below -5C is too cold
above 79C is too hot
low temperature warning below 10C
high temperature warning above 51C
IOA temperature ranges
below -5C is too cold
above 79C is too hot
low temperature warning below 10C
high temperature warning above 56CTo display the temperature status table on an E120 router:
host1#show environment table
temperature temperature slot type (10C - 56C) status ---- -------- ----------- ----------- 1 LM-10 37 normal 1/1 GE-8 IOA 35 normal 2 LM-10 37 normal 2/1 GE-8 IOA 39 normal 4 LM-10A-ADV 37 normal 6 SRP-120 40 normal 6 SFM-120 40 normal 6/0 SRP IOA 30 normal 7 SRP-120 41 normal 7 SFM-120 41 normal 8 SFM-120 31 normal 9 SFM-120 32 normal 10 SFM-120 32 normal
fabric temperature ranges
below -5C is too cold
above 79C is too hot
low temperature warning below 10C
high temperature warning above 56C
processor temperature ranges
below -5C is too cold
above 79C is too hot
low temperature warning below 10C
high temperature warning above 51C
IOA temperature ranges
below -5C is too cold
above 79C is too hot
low temperature warning below 10C
high temperature warning above 56CMeaning
Table 55 lists the show environment command output fields.
Table 55: show environment Output Fields
Field Name | Field Description |
|---|---|
chassis | Number of slots, midplane identifier, and hardware revision number:
|
fabric | Capacity and hardware revision of the fabric |
fans | Status of fans |
nvs | Status and capacity of NVS and amount of space used |
power | States of power feeds |
AC power | For ERX310 router only; states of power feeds |
srp redundancy | Availability of a redundant SRP module |
slots: cards missing or offline | Status of each slot:
|
line redundancy | Number of redundancy groups installed:
|
fabric redundancy | Status of redundancy on the switch fabric on the E120 and E320 routers:
|
temperature | Status of the system temperature |
timing | Source of the timing signal:
|
system operational | Status of the system |
slot | Number of the slot in which the module resides |
type | Type of module in the slot on the E120 and E320 routers |
temperature | Temperature of the line module, SRP module, or SFM on the E120 and E320 routers |
processor temperature | Temperature of the line module or SRP module |
processor temperature status | Temperature condition of the line module:
|
IOA temperature | Temperature of the corresponding I/O module or IOA |
IOA temperature status | Temperature condition of the corresponding I/O module or IOA:
|
processor temperature ranges | Displays the temperature ranges for the line modules and SRP modules |
IOA temperature ranges | Displays the temperature ranges for the I/O modules on ERX7xx models, ERX14xx models, and the ERX310 router or IOAs on the E120 and E320 routers |
fabric temperature ranges | Displays the temperature ranges for the SRP modules and SFMs on the E120 and E320 routers |
Hide Navigation Pane