Monitoring the Detection of Corrupted FPGA Statistics Settings
Purpose
Display the configuration details of the FPGA statistics detection utility.
Action
To display the settings of the capability to detect corruption in the FPGA statistics
host1#show fpga-stats-monitoring
FPGA statistics monitoring is enabled, threshold is 40
Meaning
Table 49 lists the show fpga-stats-monitoring command output fields.
Table 49: show fpga-stats-monitoring Output Fields
FPGA statistics monitoring | Displays whether the capability to detect corruption in the FPGA statistics is enabled or disabled. |
threshold | Threshold value to be used to compare the differential value between the interface and policy counters for ingress or egress policies. A corruption is detected if the difference between the interface and policy counters is equal to or higher than the threshold. The FPGA statistics is not corrupt if the difference between the interface and policy counters is less than the threshold. |
Related Documentation
- Detection of Corruption in the FPGA Statistics for Policies of Subscribers Managed by the SRC Software
- Computation of the Interface and Policy Counters for the Detection of Corruption in the FPGA Statistics
- Example: Computation of the Threshold Value by Using Interface and Policy Counters for the Detection of Corruption in the FPGA Statistics
- Scenarios for the Detection of Corruption in the FPGA Statistics and the Determination of the Threshold
- Configuring the Capability to Detect Corruption in the FPGA Statistics for Policies Managed by the SRC Software