| IOA label | ES2-S1 GE-4 IOA |
| Number of IOA ports | |
| Software release | |
| Description | - 21 W maximum
- Half-height module
- See Module and Slot Combinations for more
information on combining IOAs in a slot.
- Uses a range of small form-factor pluggable (SFP) transceivers
to support different modes and cable lengths.
- Uses either optical or copper SFPs.
- The optical transceivers are 1000Base-SX, 1000Base-LX,
and 1000Base-ZX compliant.
- The copper transceivers are 1000Base-T compliant.
- Single-strand SFPs can be used. These SFPs work in pairs
and require a matching SFP at the opposite end of the Ethernet connection.
For example, an SFP rated at TX 1310, RX 1550 must be paired with
an SFP rated TX 1550, RX 1310 with the same maximum operating range.
See the following corresponding table (Single-strand SFPs Pairing)
for more information.
|
| Capability | - Ethernet (IEEE 802.3x)
- 1000Base-SX/LX/ZX
|
| Software features | - See Ethernet IOAs for information
about the layer 2 and layer 3 protocols and applications that this
module combination supports.
|
| Model compatibility | |
| Line module compatibility | |
| SRP module compatibility | |
| Line module redundancy compatibility | - Can be paired with an ES2 4G LM.
- Must be installed in the same redundancy group as an ES2
4G LM and ES2–S1 REDUND IOA combination.
|
| Port redundancy support | |
| Cables and connectors (copper SFP) | - Maximum range is 100 meters on CAT5 cable.
|
| Cables and connectors (multimode
[SX] ) | - Up to four LC-style fiber-optic connectors
- Transmit power:
- Receive input power:
- See the following corresponding table (SX Fiber Optic
Cabling) for cabling requirements.
- See E120 and E320 Hardware Guide, Chapter 5,
Cabling the Router for more information.
|
| Cables and connectors (single-mode
[LX]) | - Up to four LC-style fiber-optic connectors
- Transmit power:
- Receive input power:
- See the following corresponding table (LX Fiber Optic
Cabling) for cabling requirements.
- See E120 and E320 Hardware Guide, Chapter 5,
Cabling the Router for more information.
|
| Cables and connectors (single-mode
LX40) | - Up to four LC-style fiber-optic connectors
- Transmit power:
- Receive input power:
- min: –35 dBm
- max: –22.5 dBm
- See the following corresponding table (LX40 Fiber Optic
Cabling) for cabling requirements.
- See E120 and E320 Hardware Guide, Chapter 5,
Cabling the Router for more information.
|
| Cables and connectors (single-mode
[ZX] ) | - Up to four LC-style fiber-optic connectors
- Transmit power:
- Receive input power:
- See the following corresponding table (ZX Fiber Optic
Cabling) for cabling requirements.
- See E120 and E320 Hardware Guide, Chapter 5,
Cabling the Router for more information.
|
| LEDs | When lit, LED indicates:- OK (green)—Physical link is connected properly and
is functioning properly
- FAIL (red)—Failure detected
- Port LEDs:
- LK (green)—Ethernet link is up
- ACT (green)—Blinks when there is Ethernet traffic
being received
|
| Alarms, errors, and events | - See Monitoring Ethernet Interfaces in JunosE Physical Layer Configuration Guide, Chapter 5,
Configuring Ethernet Interfaces.
|