suspicious-control-flow-detection protocol low-threshold
Syntax
suspicious-control-flow-detection protocol protocolValue
low-threshold lowThresholdValue
no suspicious-control-flow-detection protocol protocolValue low-threshold
Release Information
Command introduced in JunosE Release 7.3.0.
Description
Sets the low threshold rate at which a suspicious
flow becomes no longer suspicious for a specific protocol. The no version restores the default for a protocol, which
is a protocol-dependent non-zero numeric value.
Options
- protocolValue—Name of the
protocol
- lowThresholdValue—Threshold
value in packets per second; 0 or a number in the range 1–32767;
a value of zero means that a suspicious flow cannot change to the
nonsuspicious state via a threshold; a flow can only become nonsuspicious
via a backoff time; if the low threshold value is zero and the backoff
time is zero, the flow can only be considered nonsuspicious if the
rate (in packets per second) goes to zero
Mode
Global Configuration
Published: 2011-04-01