suspicious-control-flow-detection protocol backoff-time
Syntax
suspicious-control-flow-detection protocol protocolValue backoff-time backoffTimeValue
no suspicious-control-flow-detection protocol protocolValue backoff-time
Release Information
Command introduced in JunosE Release 7.3.0.
Description
Sets the backoff expiration time when the flow is no longer considered suspicious for a specific protocol. The no version restores the default value of 300 seconds for a protocol.
Options
- protocolValue—Name of the protocol
- backoffTimeValue—Period of time in seconds; 0 or a number in the range 10–1000; a value of zero means that a suspicious flow does not change to the nonsuspicious state because of a timeout; if the low threshold value is zero and the backoff time is zero, the flow is only considered no longer suspicious if the rate (in packets per second) goes to zero
Mode
Global Configuration