mdt-interval
Syntax
mdt-interval time
no mdt-interval
Release Information
Command introduced in JunosE Release 8.2.0.
Description
Configures the time in seconds between successive MLD join TLVs. The no version returns to the default.
Options
- time—Time between successive MLD join TLV in the range 1–300 seconds; the default is 60
Mode
IP PIM Data MDT Configuration