frame-relay lmi-n392dte
Syntax
frame-relay lmi-n392dte threshold
no frame-relay lmi-n392dte
Release Information
Command introduced before JunosE Release 7.1.0.
Description
Sets the error threshold counter (N392) on a DTE interface. The no version removes current setting and sets the default.
Options
- threshold—Positive number in the range 1–10; number of errors that will place the interface in an operationally down state; default value is 3 errors
Mode
Interface Configuration