clock source
Syntax
clock source { line | internal { module | chassis } }
no clock source
Release Information
Command introduced before JunosE Release 7.1.0.
Description
Determines how an interfaces obtains clocking signals. The no version restores the default value, line.
Options
- line—Interface clocks data from a clock recovered from the line's receive data stream; the default.
- internal—Internal clock source transmits data from
its internal clock. You must specify one of the following for internal
clocking:
- module—Internal clock is from the line module itself
- chassis—Internal clock is from the configured system clock
Mode
Controller Configuration, Interface Configuration (POS only)