| Module label | SFM-100 |
| IOA label | |
| Number of IOA ports | |
| Software release | |
| Description | - 40 W maximum
- Switch fabric module (100 Gbps)
- Works with the SRP-100 module to create a switch fabric
- Must be installed only with SRP-100 module and SFM–100
modules
|
| Capability | |
| Software features | |
| Model compatibility | |
| Line module compatibility | - ES2 4G LM
- ES2 10G UPLINK LM
|
| SRP module compatibility | - SRP-100
- Cannot use with SRP-320 module or SFM-320 module
|
| Line module redundancy compatibility | - Yes (ES2-S1 REDUND IOA must be installed in either slot
0 or slot 11)
|
| Module redundancy support | |
| Port redundancy support | |
| Cables and connectors | |
| LEDs | When lit, LED indicates:- OK (green)—Self-test passed
- FAIL (red)—Failure detected
- ONLINE (green)—Online with no alarms or errors
- REDUN (green)—N+1 redundancy is enabled; 2 SRPs
and 3 SFMs must be installed and working. When LED is unlit, one of
the five fabric slices is down or not installed; N+1 redundancy is
not enabled.
When REDUN LED is on, the module may be removed without
interrupting service. |
| Alarms, errors, and events | - See Monitoring Modules in JunosE System Basics Configuration Guide, Chapter 6, Managing
Modules.
|