| IOA label | ES2-S1 REDUND IOA |
| Number of IOA ports | |
| Software release | |
| Description | - 10 W maximum
- Full-height module
- Provides redundancy for line modules
- Inserted in slot 0 and 11 only
|
| Capability | - Provides switchover when a line module fails
- Provides N+1 redundancy for line modules
- When inserted in slot 0, provides redundancy for a failed
line module in slots 1–5. When inserted in slot 11, provides
redundancy for a failed line module in slots 12–16.
|
| Software features | - See JunosE System Basics Configuration Guide,
Chapter 6, Managing Modules.
|
| Model compatibility | |
| Line module compatibility | - ES2 4G LM
- ES2 10G UPLINK LM
- ES2 10G LM
- ES2 10G ADV LM
|
| SRP module compatibility | |
| Line module redundancy compatibility | |
| Port redundancy support | |
| Cables and connectors | |
| LEDs | - OK (green)—Self-test passed
- FAIL (red)—Failure detected
|
| Alarms, errors, and events | - See Monitoring Modules in JunosE System Basics Configuration Guide, Chapter 6, Managing
Modules.
|