path ds3 clock source
Syntax
path pathChannel ds3 ds3Channel clock source { line | internal
{ module | chassis } }
no path pathChannel ds3 ds3Channel clock source
Release Information
Command introduced before JunosE
Release 7.1.0.
Description
Configures the transmit clock source
for a DS3 signal. This command applies to a DS3 over channelized SONET
interface. The no version restores the
default value.
Options
- pathChannel—Number, in the
range 1–2147483648, that identifies the path
- ds3Channel—Number, in the
range 1–3, that identifies the path
- line—Interface transmits data from a clock recovered
from the line’s receive data stream
- internal—Interface transmits data using its internal
clock. You must specify one of the following for internal clocking:
- module—Internal clock is from the line module itself
- chassis—Internal clock is from the configured system
clock
Mode
Controller Configuration
Published: 2011-01-07