ethernet oam lfm link-monitor frame-seconds-summary
Syntax
ethernet oam lfm link-monitor frame-seconds-summary
{ threshold { high
{ highSummary | none } | low lowSummary } | window period }
no ethernet oam lfm link-monitor frame-seconds-summary [ threshold
{ high
{ highSummary | none }
| low lowSummary } | window period ]
Release Information
Command introduced in JunosE Release 11.1.0.
Description
Configures a threshold value for frame period summary
error events that triggers an action or causes an Errored Frame Seconds
Summary Event TLV to be sent to the OAM entity, or a period of time
in which frame period summary error events are counted. The no version disables monitoring of received frame period
summary error events.
 | Note:
You can configure this command multiple times to configure
combinations of high and low threshold values or a window period for
frame error events. |
Options
- link-monitor—Configures link monitoring parameters.
Link monitoring operations start automatically when Ethernet OAM is
enabled on an interface. When link monitoring operations are disabled,
the interface does not actively send or receive Event Notification
OAM PDUs
- frame-seconds-summary—Configures the threshold value
or window for frame period summary error events
- threshold—Configures a period or a value at, above,
or below which an action is triggered
- highSummary—Integer in the
range 1–65535 that is the high threshold in number of error
frame seconds, which when exceeded causes an action to be triggered.
The action that the local OAM entity performs when the high threshold
value is exceeded depends on the value configured using the ethernet oam lfm high-threshold command. There is no
default value. If you specify a high threshold option for frame period
summary error events, you must also enter the number of frames, which
when exceeded causes the configured action to be taken
- none—Removes the high threshold value for frame
period summary error events
- lowSummary—Integer in the range
0–65535 that is the low threshold in number of error frame seconds,
which when exceeded causes an Errored Frame Seconds Summary Event
TLV to be sent to the peer; default value is 0 frames. If you do not
configure a low threshold for framed symbol errors, the Link Fault
critical event PDU is not sent to the peer
- period—A window and period
of time during which framed period summary seconds are counted. Integer
in the range 10–900 seconds that is the monitoring period for
framed symbol errors; default value is 60 seconds
Mode
Interface Configuration
Published: 2011-01-10