Monitoring Redundancy in Installed Hardware
Purpose
Display redundancy information specific to the hardware installed.
Action
To display redundancy information of the hardware installed, system environment information, and detailed information on the temperature status of an ERX7xx router.
host1#show environment all
chassis: 14 slot (id 0x3, rev. 0x0)
fabric: 5 Gbps (rev. 1)
fans: ok
nvs: ok (81MB flash disk, 54% full)
power: A ok, B not present
AC power: A not present, B not present
srp redundancy: none
*** slots: cards missing or offline
online: 6 9
standby: 8
offline: 2
empty: 0 1 3 4 5 7 10 11 12 13
line redundancy: 1 redundancy group(s)
width 6, spare 8, primary 9
temperature: ok
timing: primary
primary: internal SC oscillator (ok)
secondary: internal SC oscillator (ok)
tertiary: internal SC oscillator (ok)
auto-upgrade enabled
*** system operational: no processor processor IOA IOA
temperature temperature temperature temperature
slot (10C - 70C) status (10C - 70C) status
---- ----------- ----------- ----------- -----------
0 31 normal 30 normal
3 31 normal 30 normal
5 31 normal 30 normal
7 31 normal 30 normal
processor temperature ranges
below -5C is too cold
above 80C is too hot
low temperature warning below 10C
high temperature warning above 70C
IOA temperature ranges
below -5C is too cold
above 80C is too hot
low temperature warning below 10C
high temperature warning above 70CTo display redundancy information of the hardware installed, system environment information, and detailed information on the temperature status of an E320 router.
host1#show environment all
chassis: 17 slot (id 0x3, rev. 0x0)
fabric: 100 Gbps (rev. 1)
fans: fanSubsystemOk
nvs: ok (977MB flash disk, 29% full), matches running config
power: A ok, B not present
srp redundancy: mode is file-system-synchronization auto-sync
enabled, switch-on-error enabled
status unknown
*** slots: cards missing or offline
online: 0 6 13
offline: 7
empty: 1 2 3 4 5 11 12 14 15 16
fabric slots: ok
online: 6 7 8 9 10
line redundancy: none
line card HA:
high availability is configured on slots:
{0, 13}
high availability state is active on slots:
{0, 13}
temperature: ok
timing: primary
primary: internal SC oscillator (ok)
secondary: internal SC oscillator (ok)
tertiary: internal SC oscillator (ok)
auto-upgrade enabled
fabric redundancy: ok*** system operational: no
temperature temperature slot type (10C - 70C) status ---- ------------------ ----------- ----------- 0 LM-4 42 normal 0/1 GE-4 IOA 23 normal 6 SRP-100 32 normal 6 SFM-100 32 normal 6/0 SRP IOA 25 normal 7 SFM-100 30 normal 8 SFM-100 23 normal 9 SFM-100 25 normal 10 SFM-100 24 normal 13 LM-4 24 normal 13/0 GE-4 IOA 23 normal
fabric temperature ranges
below -5C is too cold
above 79C is too hot
low temperature warning below 10C
high temperature warning above 70C
processor temperature ranges
below -5C is too cold
above 79C is too hot
low temperature warning below 10C
high temperature warning above 70C
IOA temperature ranges
below -5C is too cold
above 79C is too hot
low temperature warning below 10C
high temperature warning above 70CMeaning
Table 5 lists the show environment command output fields.
Table 5: show environment Output Fields
Field Name | Field Description |
|---|---|
Chassis | Number of slots, midplane identifier, and hardware revision number:
|
fabric | Capacity and hardware revision of the fabric. |
fans | Status of fans. |
nvs | Status and capacity of NVS and amount of space used. |
power | Status of power feeds. |
AC power | For ERX310 router only; status of power feeds. |
srp redundancy | Availability of a redundant SRP module |
slots: cards missing or offline. | Status of each slot:
|
line redundancy | Number of redundancy groups installed:
|
fabric redundancy | Status of redundancy on the switch fabric on the E120 and E320 routers. Possible values: ok and none. |
line card HA | Configuration details for stateful line module switchover on E120 and E320 routers
|
temperature | Status of the system temperature |
timing | Source of the timing signal:
|
system operational | Status of the system |
slot | Number of the slot in which the module resides |
type | Type of module in the slot on the E120 and E320 routers |
temperature | Temperature of the line module, SRP module, or SFM on the E120 and E320 routers |
processor temperature | Temperature of the line module or SRP module |
processor temperature status | Temperature condition of the line module:
|
IOA temperature | Temperature of the corresponding I/O module or IOA |
IOA temperature status | Temperature condition of the corresponding I/O module or IOA:
|
processor temperature ranges | Temperature ranges for the line modules and SRP modules. |
IOA temperature ranges | Temperature ranges for the I/O modules on ERX7xx models, ERX14xx models, and the ERX310 router or IOAs on the E120 and E320 routers. |
fabric temperature ranges | Temperature ranges for the SRP modules and SFMs on the E120 and E320 routers. |
Hide Navigation Pane
Show Navigation Pane
SHA1