| Line module label | COCX-F3 |
| I/O module label | E3-12 FRAME I/O |
| Number of I/O ports | |
| Software release | - First supported: 4.0.2
- Final supported: 14.0.x
|
| Description | - 135 W
- Unchannelized E3 for Frame
|
| Type | |
| Capability | |
| Software features | - See ERX Module Guide, Appendix A, Module Protocol
Support for information about the layer 2 and layer 3 protocols
and applications that this module combination supports.
|
| Model compatibility | - ERX7xx models
- ERX14xx models
- ERX310 router
|
| SRP module compatibility | - SRP-5G+
- SRP-10G
- SRP-40G
- SRP-40G PLUS
- SRP-SE10G
|
| Module redundancy support | - 1:N redundancy
- NOTE: Line module redundancy
is not supported on the ERX310 router.
|
| Cables and connectors | - BT43 SMB connector
- Cable that adapts to 75-ohm BNC is available.
- The transmitted signal complies with ITUT G.703, Physical/electrical
characteristics of hierarchical digital interfaces (November 2001)
for cable lengths from 0–137 m (0–450 feet).
- See ERX Hardware Guide, Chapter 5, Cabling
ERX Routers for more information.
|
| LEDs | - See ERX Module Guide, Appendix B, Module LEDs.
|
| Alarms, errors, and events | - See Monitoring Interfaces in JunosE Physical Layer Configuration Guide, Chapter 2, Configuring
T3 and E3 Interfaces.
|