Monitoring Redundancy in Line Module and SRP Modules
Purpose
Display redundancy information about SRP modules, line modules, and I/O modules in ERX7xx models, ERX14xx models, and the ERX310 router. Also displays redundancy information about SRP modules, line modules, and IOAs in the E120 router and the E320 router.
Action
To display redundancy information about the SRP modules, line modules, and I/O modules on an ERX7xx router.
host1#show hardware
serial assembly assembly ram
slot type number number rev. (MB)
---- ---------------- ---------- ---------- -------- ----
0 SRP-10Ge 4305358981 3500005472 A06 2048
1 SRP-10Ge 4305359020 3500005472 A06 2048
2 --- --- --- --- ---
3 --- --- --- --- ---
4 CT3-12 4305337201 3500010901 A07 128
5 OC3/OC12/DS3-ATM 4605300290 3500103958 A06 256
6 GE/FE 4605340294 3500104554 A08 256
number
of
serial assembly assembly MAC
slot type number number rev. addresses
---- ------------- ---------- ---------- -------- ---------
0 --- --- --- --- ---
1 SRP-10Ge I/O 4605250426 3500003302 A02 1
2 --- --- --- --- ---
3 --- --- --- --- ---
4 CT3/T3-12 I/O 4305316605 3500010801 A02
5 OC3(8)-MM I/O 4304443600 4500001501 A03 4
6 GE-SFP I/O 4605310064 4500002001 A05 1
base
slot MAC address
---- --------------
0 ---
1 0090.1aa0.577a
2 ---
3 ---
4
5 0090.1a41.7c68
6 0090.1aa0.6216To display redundancy information about the SRP modules, line modules, and IOAs on the E320 router.
host1#show hardware
Chassis
-------
serial assembly assembly Major/Minor
type number number rev. rev
------- ---------- ---------- -------- -----------
Chassis 5504200687 4400006402 01 0.101 Modules
-------
serial assembly assembly ram Major/Min
slot type number number rev. (MB) rev
---- ------- ---------- ---------- -------- ---- ---------
0 --- --- --- --- --- ---
1 --- --- --- --- --- ---
2 LM-4 4303470363 4500006301 01 256 1.101
3 --- --- --- --- --- ---
4 --- --- --- --- --- ---
5 --- --- --- --- --- ---
6 --- --- --- --- --- ---
6 --- --- --- --- --- ---
7 SRP-100 4304218323 4500006601 03 1024 1.103
7 SFM-100 4304218323 4500006601 03 --- 1.103
8 SFM-100 4304206756 4500006701 04 --- 1.104
9 SFM-100 4304206762 4500006701 04 --- 1.104
10 SFM-100 4304206737 4500006701 04 --- 1.104
11 --- --- --- --- --- ---
12 --- --- --- --- --- ---
13 --- --- --- --- --- ---
14 --- --- --- --- --- ---
15 --- --- --- --- --- ---
16 --- --- --- --- --- --- Adapters
--------
number
of
serial assembly assembly MAC
slot type number number rev. addresses
---- -------- ---------- ---------- -------- ---------
0/0 --- --- --- --- ---
0/1 --- --- --- --- ---
1/0 --- --- --- --- ---
1/1 --- --- --- --- ---
2/0 GE-4 IOA 4304020462 4500006800 11 4
2/1 --- --- --- --- ---
3/0 --- --- --- --- ---
3/1 --- --- --- --- ---
4/0 --- --- --- --- ---
4/1 --- --- --- --- ---
5/0 --- --- --- --- ---
5/1 --- --- --- --- ---
7/0 SRP IOA 4303470366 4500006500 02 2
11/0 --- --- --- --- ---
11/1 --- --- --- --- ---
12/0 --- --- --- --- ---
12/1 --- --- --- --- ---
13/0 --- --- --- --- ---
13/1 --- --- --- --- ---
14/0 --- --- --- --- ---
14/1 --- --- --- --- ---
15/0 --- --- --- --- ---
15/1 --- --- --- --- ---
16/0 --- --- --- --- ---
16/1 --- --- --- --- ---
base Major/Minor
slot MAC address rev
---- -------------- -----------
0/0 --- ---
0/1 --- ---
1/0 --- ---
1/1 --- ---
2/0 0090.1a00.17ec 1.111
2/1 --- ---
3/0 --- ---
3/1 --- ---
4/0 --- ---
4/1 --- ---
5/0 --- ---
5/1 --- ---
7/0 0090.1a00.17ae 1.102
11/0 --- ---
11/1 --- ---
12/0 --- ---
12/1 --- ---
13/0 --- ---
13/1 --- ---
14/0 --- ---
14/1 --- ---
15/0 --- ---
15/1 --- ---
16/0 --- ---
16/1 --- --- Fan(s)
------
serial assembly assembly Major/Minor
Tray type number number rev. rev
---- ----------- ---------- ---------- -------- -----------
0 Primary FAN 4303370009 4400007000 01 1.101
--- --- --- --- --- ---Meaning
Table 6 lists the show hardware command output fields.
Table 6: show hardware Output Fields
Field Name | Field Description |
|---|---|
Slot | Physical slot that contains the module. |
type | Kind of module or chassis and fan tray in the E120 and E320 routers; an “e” at the end of an SRP module type (for example, SRP-5Ge) indicates that the module includes error-checking code (ECC) memory. |
serial number | Serial number of the module, chassis, or fan tray. |
assembly number | Part number of the module, chassis, or fan tray. |
assembly rev. | Hardware revision of the module, chassis, or fan tray. |
ram (MB) | Memory capacity of the host processor. |
number of MAC addresses | Total number of Ethernet addresses on an I/O module or an IOA. |
base MAC address | Lowest Ethernet address on an I/O module or an IOA |
Tray | Number of the fan tray in the E120 and E320 routers; 0 indicates the primary fan. |
Major/Minor rev | Revision number of the module on the E120 and E320 routers. |
Hide Navigation Pane
Show Navigation Pane
SHA1