Monitoring the Redundancy Status of Line Modules
Purpose
Display redundancy information specific to line modules.
Action
To display the redundancy status of the line modules.
host1#show redundancy line-card
automatic reverting is off
backed
up sparing
hardware lockout by for revert
slot role config slot slot at
---- -------- --------- ------ ------- ------
3 --- --- --- --- ---
8 spare --- --- --- ---
12 primary protected --- --- ---midplane midplane slots type rev ------ -------- -------- 8 - 13 6 0
Meaning
Table 12 lists the show redundancy line-card command output fields.
Table 12: show redundancy line-card Output Fields
Field Name | Field Description |
|---|---|
automatic reverting | State of automatic reverting (on or off). |
slots | Slots in which the line modules reside. |
hardware role | Function of the line module: primary or spare. |
lockout config | Status of redundancy on this line module:
|
backed up by slot | Slot that contains the line module that is a spare for this primary line module. |
sparing for slot | Slot that contains the primary line module for which this line module is a spare. |
revert at | Time at which you want line module to revert. |
midplane type | Identifier for the type of midplane. |
midplane rev | Hardware revision number of the redundancy midplane. |