frame-relay lmi-n392dce
Syntax
frame-relay lmi-n392dce threshold
no frame-relay lmi-n392dce
Release Information
Command introduced before JunosE Release 7.1.0.
Description
Sets the error threshold counter (N392) on a DCE interface. The no version removes current setting and sets the default.
Options
- threshold—Positive number in the range 1– 10; number of errors that will place the interface in an operationally down state; default value is 2 errors
Mode
Interface Configuration