| Line module label | X.21/V.35 |
| I/O module label | X.21/V.35 I/O |
| Number of I/O ports | |
| Software release | - First supported: 2.10.1, 3.3.2
- Final supported: 7.3.x
|
| Description | - 60 W
- X.21/V.35 synchronous serial interface
|
| Type | |
| Capability | |
| Software features | - See ERX Module Guide, Appendix A, Module Protocol
Support for information about the layer 2 and layer 3 protocols
and applications that this module combination supports.
|
| Model compatibility | - ERX7xx models
- ERX1410 router
|
| SRP module compatibility | |
| Module redundancy support | |
| Cables and connectors | - 200-pin proprietary socket on I/O module
- DB15 X.21 or DB34 V.35 at remote end
- Serial signals can travel a limited distance without significant
degradation. Slower serial signals can travel farther without degradation
than faster serial signals. See “Cable Lengths” row for
the maximum cable lengths you can use to prevent signal degradation
at various transmission speeds.
|
| Cable Lengths | |
Transmission Speed (Hz)- 2400
- 4800
- 9600
- 19200
- 38400
- 56000
- 2048000
| Cable Length (Meters/Feet)- 1250/4100
- 625/2050
- 312/1025
- 156/513
- 78/256
- 31/102
- 8/25
|
| LEDs | - See ERX Module Guide, Appendix B, Module LEDs.
|
| Alarms, errors, and events | - See Monitoring Interfaces in the Configuring X.21/V.35 Interfaces chapter of the JunosE Physical Layer Configuration Guide for Release
8.0.x and earlier.
|