Monitoring the Redundancy Status of Line Modules

Purpose

Display redundancy information specific to line modules.

Action

To display the redundancy status of the line modules. 

host1#show redundancy line-card
automatic reverting is off
                              backed
                                up     sparing
       hardware    lockout      by       for     revert
slot     role      config      slot     slot       at
----   --------   ---------   ------   -------   ------
 3       ---         ---       ---       ---      ---
 8      spare        ---       ---       ---      ---
 12    primary    protected    ---       ---      ---
         midplane   midplane
slots      type       rev
------   --------   --------
8 - 13      6          0

Meaning

Table 9 lists the show redundancy line-card command output fields.

Table 9: show redundancy line-card Output Fields

Field Name

Field Description

automatic reverting

State of automatic reverting (on or off)

slots

Slots in which the line modules reside

hardware role

Function of the line module: primary or spare

lockout config

Status of redundancy on this line module (protected—Line module redundancy is enabled; locked out—Line module redundancy is disabled)

backed up by slot

Slot that contains the line module that is a spare for this primary line module

sparing for slot

Slot that contains the primary line module for which this line module is a spare

revert at

Time at which you want line module to revert

midplane type

Identifier for the type of midplane

midplane rev

Hardware revision number of the redundancy midplane