[Contents][Prev][Next][Report an Error]
IOA Slot Combinations
Depending on the software release and IOA type, you must install IOAs
in certain slots and bays combined with other IOAs in the same slot:
- You must insert some IOAs only in the upper bay or right bay (Adapter
0) of each IOA module slot. If you insert one of these IOAs into a lower bay
or left bay (Adapter 1) slot, the line module diagnostics fail, an error message
states that the bottom slot is not supported for the currently installed software
release, and the slot is disabled.
- If you insert an unrecognized IOA, such as an IOA that is not
supported by a particular software release, the line module diagnostics fail,
an error is generated, and the slot is disabled.
- If you remove an IOA and replace it with a different IOA in the
same slot, an error message states the mismatch and the slot is disabled.
- Full-height IOAs take up the entire slot (both Adapter 0 and Adapter
1).
For information about working with modules and IOAs, see JUNOSe
System Basics Configuration Guide, Chapter 6, Managing Modules.
See Table 23 for currently available IOAs and the
bays in which you may insert them.
Table 23: IOA Locations
and Combinations
|
IOA
|
Upper/Right Bay (Adapter 0)
|
Lower/Left Bay (Adapter 1)
|
Both Bays Concurrently
|
Combined with Other IOAs in Same Slot
|
|
ES2-S1 GE-4
|
Yes
|
Yes
|
No
|
No
|
|
ES2-S1 GE-8
|
Yes
|
Yes
|
Yes
|
Yes (GE-8 when paired with ES2 4G LM or ES2 10G LM; GE-8, OC3/STM1,
and OC12/STM4 IOAs when paired with ES2 4G LM)
|
|
ES2-S1 10GE
|
Yes
(Full-height IOA)
|
Not applicable
|
Not applicable
|
Not applicable
|
|
ES2-S2 10GE PR
|
Yes
(Full-height IOA)
|
Not applicable
|
Not applicable
|
Not applicable
|
|
ES2-S1 OC3-8 STM1 ATM
|
Yes
|
Yes
|
Yes
|
Yes (GE-8, OC3/STM1, and OC12/STM4 IOAs only)
|
|
ES2-S1 OC12-2 STM4 ATM
|
Yes
|
Yes
|
Yes
|
Yes (GE-8, OC3/STM1, and OC12/STM4 IOAs only)
|
|
ES2-S1 OC12-2 STM4 POS
|
Yes
|
Yes
|
Yes
|
Yes (GE-8, OC3/STM1, and OC12/STM4 IOAs only)
|
|
ES2-S1 OC48 STM16 POS
|
Yes
|
Yes
|
No
|
No
|
|
ES2-S1 SERVICE
|
Yes
(Full-height IOA)
|
Not applicable
|
Not applicable
|
Not applicable
|
|
ES2-S1 REDUND
|
Yes
(Full-height IOA; slots 0 and 11 only)
|
Not applicable
|
Not applicable
|
Not applicable
|
[Contents][Prev][Next][Report an Error]