Verifying Switching Mode Configuration on J Series uPIMs
The operational mode command for checking the status and statistics for multiport uPIMs in switching mode is different from that in routing mode. For uPIMs in routing mode, the operational commands are the same as for other Gigabit Ethernet interfaces, such as the 1-port Gigabit Ethernet ePIM and built-in Gigabit Ethernet ports.
However, not all operational mode commands are supported for ports of a uPIM in switching mode. For example, the operational mode command for monitoring port statistics is not supported.
Before You Begin |
|---|
![]() | Note: To clear the statistics for the individual switch ports, use the clear interfaces statistics ge-pim/0/0 switch-port port-number command. |
To verify the status and view statistics for a port on a uPIM in switching mode:
Port 0, Physical link is Up
Speed: 100mbps, Auto-negotiation: Enabled
Statistics: Receive Transmit
Total bytes 28437086 21792250
Total packets 409145 88008
Unicast packets 9987 83817
Multicast packets 145002 0
Broadcast packets 254156 4191
Multiple collisions 23 10
FIFO/CRC/Align errors 0 0
MAC pause frames 0 0
Oversized frames 0
Runt frames 0
Jabber frames 0
Fragment frames 0
Discarded frames 0
Autonegotiation information:
Negotiation status: Complete
Link partner:
Link mode: Full-duplex, Flow control: None, Remote fault: OK, Link partner Speed: 100 Mbps
Local resolution:
Flow control: None, Remote fault: Link OK
Hide Navigation Pane
Show Navigation Pane
Download
SHA1