test-only-mode

Syntax

test-only-mode (true | false):

Hierarchy Level

[edit services unified-access-control ]

Release Information

Statement introduced in Release 9.4 of Junos OS.

Description

Configure the device in test-only mode to log access decisions from the Infranet Controller without actually enforcing the decisions. When configured in test-only mode, the SRX Series device enables all UAC traffic to go through so you can test the implementation without impeding traffic.

Use this statement when you are configuring the SRX Series device to act as a Junos OS Enforcer in a Unified Access Control (UAC) deployment. When deployed as a Junos OS Enforcer, the SRX Series device enforces the policies that are defined on the UAC’s Infranet Controller.

Usage Guidelines

For configuration instructions and examples, see the Junos OS Security Configuration Guide.

Required Privilege Level

services—To view this statement in the configuration.

services-control—To add this statement to the configuration.