show chassis cluster data-plane interfaces
Syntax
show chassis cluster data-plane interfaces
Release Information
Command introduced in Release 10.2 of Junos OS.
Description
Display the status of the data plane interface (also known as a fabric interface) in a chassis cluster configuration.
Required Privilege Level
view
List of Sample Output
show chassis cluster data-plane interfacesOutput Fields
Table 9 lists the output fields for the show chassis cluster data-plane interfaces command. Output fields are listed in the approximate order in which they appear.
Table 9: show chassis cluster data-plane interfaces Output Fields
Field Name | Field Description |
|---|---|
fab0/fab1 | Name of the logical fabric interface.
|
Sample Output
show chassis cluster data-plane interfaces
user@host> show
chassis cluster data-plane interfaces fab0:
Name Status
ge-2/1/9 up
ge-2/2/5 up
fab1:
Name Status
ge-8/1/9 up
ge-8/2/5 up