hold-down-interval
Syntax
hold-down-interval number;
Hierarchy Level
[edit chassis cluster redundancy-group group-number]
Release Information
Statement introduced in Release 10.0 of Junos OS.
Description
Set the minimum interval to be allowed between back-to-back failovers for the specified redundancy group (affects manual failovers, as well as automatic failovers associated with monitoring failures).
For redundancy group 0, this setting prevents back-to-back failovers from occurring less than 5 minutes (300 seconds) apart. Note that a redundancy group 0 failover implies a Routing Engine failure.
Options
number—Number of seconds specified for the interval.
- Range: For redundancy group 0, 300 through 1800 seconds; for redundancy group 1 through 128, 0 through 1800 seconds.
- Default: For redundancy group 0, 300 seconds; for redundancy group 1 through 128, 1 second.
Usage Guidelines
For configuration instructions and examples, see the Junos OS Security Configuration Guide.
Required Privilege Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.