control-ports
Syntax
Hierarchy Level
Release Information
Statement introduced in Release 9.2 of Junos OS. Support for dual control ports added in Release 10.0 of Junos OS.
Description
Enable the specific control port of the Services Processing Card (SPC) for use as a control link for the chassis cluster. By default, all control ports are disabled. User needs to configure a minimum of one control port per chassis of the cluster. If user configures port 0 only, the Juniper Services Redundancy Protocol process (jsrpd) does not send control heartbeats on control link 1 and the counters it sends will show zeroes.
Options
fpc slot-number —Flexible PIC Concentrator (FPC) slot number
![]() | Note: FPC slot range depends on platform. The maximum range of 0 through 23 applies to SRX5800 devices; for SRX5600 devices, the only applicable range is 0 through 11. |
port port-number —Port number on which to configure the control port.
Usage Guidelines
For configuration instructions and examples, see the Junos OS Security Configuration Guide.
Required Privilege Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.