| Description
|
-
Two or four DS3 ports
-
Power requirement: 0.47 A/48 V @ 22.5 W
-
Integrated DSU interoperability with leading DSU vendors
|
| Hardware features
|
-
High-performance throughput on all ports at speeds up to 44.736
Mbps, full duplex
-
C-bit framing
-
B3ZS line encoding
-
Subrate and scrambling:
-
Digital Link
-
Kentrox
-
Larscom
-
Per-port rate policing on input
-
Per-port rate shaping on output
-
Packet buffering, Layer 2 parsing
|
| Software features
|
-
DS3 functionality:
-
C-bit framing
-
B3ZS line encoding
-
DS3 diagnostics and loopback control
-
DS3 alarm and event counting and detection
-
Per-packet counts and byte counts
-
Local and remote loopback testing, as well as BERT testing per
DS3
-
DS3 Far-end Alarm and Control (FEAC) channel support
-
Encapsulations:
-
High-level Data Link Control (HDLC)
-
Frame Relay
-
Multiprotocol Label Switching (MPLS) circuit cross-connect (CCC)
-
Point-to-Point Protocol (PPP)
|
| Cables and connectors
|
-
Custom 10-ft (3.05-m) posilock SMB to BNC male cable, separate
RX and TX (provided)
|
| LEDs
|
One tricolor per port:
-
Off—Not enabled
-
Green—Online with no alarms or failures
-
Amber—Online with alarms for remote failures
-
Red—Active with a local alarm; router has detected a failure
|
| Alarms, errors, and events
|
-
Alarm Indication Signal (AIS)
-
Bit Error Rate Test (BERT) functionality on PIC (you can configure
one DS3 channel in BERT mode and configure the remaining channels to transmit
and receive normal traffic)
-
Equipment failure (Does not affect service)
-
Far-end Block Error (FEBE)
-
Frame error
-
Idle code, Idle received
-
Local and remote loopback
-
Loss of Signal (LoS)
-
Out of Frame (OoF)
-
Parity bit (P-bit) disagreements
-
Path parity error
-
Yellow alarm bit (X-bit) disagreements
|