[Contents] [Prev] [Next] [Report an Error]

Remove a PIC

To remove a PIC, follow this procedure (see Figure 30):

  1. Place an electrostatic bag or antistatic mat on a flat, stable surface to receive the PIC. If the PIC connects to fiber-optic cable, have ready a rubber safety cap for each transceiver and cable.
  2. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and connect the strap to one of the ESD points on the chassis. For more information about ESD, see Prevent Electrostatic Discharge Damage.
  3. If the PIC has multiple cable connector ports, label the cable connected to each port, to make it easier to reconnect the cables correctly.
  4. Use one of the following methods to take the PIC offline:
  5. Disconnect the cables from the PIC. If the PIC uses fiber-optic cable, immediately cover each transceiver and the end of each cable with a rubber safety cap.

    Do not look directly into the ends of fiber-optic cables or into the transceivers on the interface faceplate. Single-mode fiber-optic cable and the interfaces that use it (such as ATM and SONET/SDH interfaces) emit laser light that can damage your eyes.

    Do not leave a fiber-optic transceiver uncovered except when inserting or removing cable. The safety cap keeps the port clean and prevents accidental exposure to laser light.

  6. Arrange the cable in the cable management system to prevent it from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly coiled loop in the cable management system. Placing fasteners on the loop helps to maintain its shape.

    Avoid bending fiber-optic cable beyond its minimum bend radius. An arc smaller than a few inches in diameter can damage the cable and cause problems that are difficult to diagnose.

  7. Unseat the PIC from the chassis:
  8. Grasp both sides of the PIC faceplate and slide it out of the chassis. Do not use the ejector lever as a handle.
  9. Place the PIC in the electrostatic bag or on the antistatic mat.
  10. If you are not reinstalling a PIC into the emptied slot within a short time, install a blank PIC panel over the slot to maintain proper airflow in the chassis.

Figure 30: Remove a PIC

Image g001310.gif


[Contents] [Prev] [Next] [Report an Error]