Maintain the Routing Engine

The Routing Engine installs into a slot in the Forwarding Engine Board (FEB) at the rear of the chassis, as shown in Figure 3. To maintain the Routing Engines, issue the CLI show chassis routing-engine command on a regular basis to check the status of the Routing Engine:


user@host> show chassis routing-engine
Routing Engine status:
    Temperature          35 degrees C / 95 degrees F
    DRAM                768 MB
    Memory utilization   16 percent
    CPU utilization:
      User                0 percent
      Background          0 percent
      Kernel              0 percent
      Interrupt           0 percent
      Idle              100 percent
    Model                   RE-2.0
    Serial ID               f1000004f91d2901
    Start time              2003-05-01 15:07:12 PDT
    Uptime                  3 days, 9 hours, 4 minutes, 5 seconds
    Load averages:          1 minute   5 minute  15 minute
                                0.04       0.01       0.00

 

For further description of the output from the command, see the JUNOS Internet Software Operational Mode Command Reference: Protocols, Class of Service, Chassis, and Management.