[Contents] [Prev] [Next] [Index] [Report an Error]


Troubleshoot FPCs

As soon as an FPC is seated on an operating router, the Routing Engine downloads the FPC software to it. The FPC then runs diagnostics and enables the PICs that it houses. During this time, the green FPC LED labeled OK on the craft interface is blinking. When the FPC is online and functioning normally, the OK LED lights steadily.

To troubleshoot FPCs, follow these guidelines:

user@host> show chassis fpc
                 Temp  CPU Utilization (%)   Memory    Utilization (%)
Slot State        (C)  Total  Interrupt      DRAM (MB) Heap     Buffer
  0  Online        28      1          0         8         9         15
  1  Online        27      1          0         8         9         15
  2  Online        29      1          0         8        12         14
  3  Empty           
  4  Empty           
  5  Online        25      0          0         8         8         14
  6  Online        29      1          0         8         9         14
  7  Online        26      1          0         8         8         13

For more detailed output, add the detail option. The following example also specifies a slot number (0), which is optional:

user@host> show chassis fpc detail 0
Slot 0 information:
  State                          Online    
  Logical slot                 0
  Temperature                 28 degrees C / 82 degrees F
  Total CPU DRAM               8 MB
  Total SRAM                   1 MB
  Total SDRAM                128 MB
  Total notification SDRAM    24 MB
  I/O Manager ASIC information   Version 1.1, Foundry IBM, Part number 0
  Start time:                    2003-05-23 18:14:31 PDT
  Uptime:                         34 days, 6 hours, 9 minutes, 5 seconds