Install a PIC Cable
- Have ready a length of the type of cable used by the PIC, as specified in the M20 and M40 Internet Routers PIC Guide. Figure 86 depicts the connector on fiber-optic cable.
![]()
- Remove the rubber safety plug from the PIC cable connector port.
- Insert the cable connector into the cable connector port on the PIC faceplate (see Figure 87, which shows a fiber-optic connector).
- Carefully thread the cable through in the cable management system, to prevent the cable from dislodging or developing stress points. Secure the cable so that it is not supporting its own weight as it hangs from the connector. Place excess cable out of the way in a neatly coiled loop in the cable management system. Placing fasteners on the loop helps to maintain its shape.
- Verify that the PIC is functioning correctly by noting whether the normal function indicator LED is lit. The normal function indicator LED is usually green; for more information, see the M20 and M40 Internet Routers PIC Guide.
You can also verify correct PIC functioning by issuing the
show chassis fpc pic-statuscommand, described in Maintain FPCs and PICs.
![]()