[Contents] [Prev] [Next] [Index] [Report an Error]


Routing Engine Interface Cable and Wire Specifications

For management and service operations, you connect the Routing Engine to an external console or management network through ports on the craft interface. You can also connect the router to external alarm-reporting devices through the alarm relay contacts on the craft interface. (For more information, see Craft Interface.)

Table 17 lists the specifications for the cables that connect to management ports and the wires that connect to the alarm relay contacts.


Table 17: Routing Engine Interface Cable and Wire Specifications

Cable Type
Cable Specification
Cable/Wire Supplied
Maximum Length
Router Receptacle
Routing Engine console or auxiliary interface
RS-232 (EIA-232) serial cable
One 6-ft (1.83-m) length with DB-9/DB-9 connectors
6 ft (1.83 m)
DB-9 male
Routing Engine Ethernet interface
Category 5 cable or equivalent suitable for 100BaseT operation
One 15-ft (4.92-m) length with RJ-45/RJ-45 connectors
328 ft (100 m)
RJ-45 autosensing
Alarm relay contacts
28-AWG to 14-AWG (0.09 to 2.09 mm2) wire
No
None