Software release
- JUNOS 4.1 and later
Description
- One OC48 port
- Power requirements: 0.86 A @ 48 V (41.4 W)
Hardware features
- Multiplexing and demultiplexing
- Rate policing on input
- Rate shaping on output
- Packet buffering, Layer 2 parsing
Software features
- SONET/SDH framing
- Link aggregation
- Alarm and event counting and detection
- Dual-router automatic protection switching (APS)
- Multiprotocol Label Switching (MPLS) fast reroute
- Encapsulations:
- High-Level Data Link Control (HDLC)
- Frame Relay
- Circuit cross-connect (CCC)
- Translational cross-connect (TCC)
- Point-to-Point Protocol (PPP)
Cables and connectors To extend the life of the laser, when a PIC is not being actively used with any valid links, take the PIC offline until you are ready to establish a link to another device. For information about taking a PIC offline, see the request chassis pic offline command in the JUNOS System Basics and Services Command Reference.
- Duplex LC/PC Connector (Rx and Tx)
- Optical interface support—see Table 6
LEDs One tricolor per port:
- Off—Not enabled
- Green—Online with no alarms or failures
- Amber—Online with alarms for remote failures
- Red—Active with a local alarm; router has detected a failure
Alarms, errors, and events
- SONET alarms:
- Alarm indication signal—line (AIS-L)
- Alarm indication signal—path (AIS-P)
- Bit error rate signal degrade (BERR-SD)
- Bit error rate signal fail (BERR-SF)
- Bit interleaved parity (BIP) error B1
- Bit interleaved parity (BIP) error B2
- Bit interleaved parity (BIP) error B3
- Loss of frame (LOF)
- Loss of pointer (LOP-P)
- Loss of signal (LOS)
- Far-end bit error: remote error indication—line (REI-L) (CV-LFE)
- Far-end bit error: remote error indication—path (REI-P) (CV-PFE)
- Payload mismatch (path label mismatch) (PLM-P)
- Payload unequipped (unequipped STS at path level) (UNEQ-P)
- Remote defect indication—line (RDI-L)
- Remote defect indication—path (RDI-P)
- SDH alarms:
- Multiplex section alarm indication signal (MS-AIS)
- Administrative unit alarm indication signal (AU-AIS)
- Bit error rate signal degrade (BERR-SD)
- Bit error rate signal fail (BERR-SF)
- Bit interleaved parity (BIP) error B1
- Bit interleaved parity (BIP) error B2
- Bit interleaved parity (BIP) error B3
- Loss of frame (LOF)
- Loss of pointer (HP-LOP)
- Loss of signal (LOS)
- Multiplex section remote error indication (MS-REI)
- Higher path label mismatch (HP-PLM)
- Higher path unequipped (HP-UNEQ)
- Multiplex section remote defect indication (MS-RDI)
- Higher path remote defect indication (HP-RDI)
- Errored seconds (ES-S, ES-L, ES-P), Far-end errored seconds (ES-LFE, ES-PFE), Far-end severely errored seconds (SES-LFE, SES-PFE), Far-end unavailable seconds (UAS-LFE, UAS-PFE)
- Severely errored framing (SEF), Severely errored framing seconds (SEFS-S), Severely errored seconds (SES-S, SES-L, SES-P), Unavailable seconds (UAS-L, UAS-P)
Table 6: Optical Interface Support for SONET/SDH OC48c/STM16 PICs