As soon as an FPC is seated on an operating router, the Routing Engine downloads the FPC software to it. The FPC then runs diagnostics and enables the PICs housed on it. During this time, the green FPC LED labeled OK on the craft interface is blinking. When the FPC is online and functioning normally, the OK LED lights steadily.
To troubleshoot the FPCs, follow these guidelines:
user@host> show chassis fpc
Temp CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt DRAM (MB) Heap Buffer 0 Online 37 4 0 32 1 39 1 Online 39 4 0 32 1 39 2 Empty 3 Online 34 4 0 32 1 39
For more detailed output, add the detail option. The following example also specifies a slot number (0), which is optional:
user@host> show chassis fpc detail 0
Slot 0 information: State Online Temperature 37 degrees C / 98 degrees F Total CPU DRAM 32 MB Total SRAM 4 MB Total SDRAM 128 MB I/O Manager ASIC information Version 3.0, Foundry IBM, Part number 0 I/O Manager ASIC information Version 3.0, Foundry IBM, Part number 0 Start time: 2003-03-31 20:54:30 PDT Uptime: 25 days, 8 hours, 5 minutes, 32 seconds