Routing Engine Interface Cable and Wire Specifications

For management and service operations, you connect the Routing Engine to an external console or management network through ports on the craft interface. You can also connect the router to external alarm-reporting devices through the alarm relay contacts on the craft interface. (For more information, see Craft Interface.)

Table 29 lists the specifications for the cables that connect to management ports and the wires that connect to the alarm relay contacts.

Table 29: Cable and Wire Specifications for Routing Engine Management and Alarm Interfaces

Port

Cable Specification

Cable/Wire Supplied

Maximum Length

Router Receptacle

Routing Engine console or auxiliary interface

RS-232 (EIA-232) serial cable

One 6-ft (1.83-m) length with DB-9/DB-9 connectors

6 ft (1.83 m)

DB-9 male

Routing Engine Ethernet interface

Category 5 cable or equivalent suitable for 100BaseT operation

One 15-ft (4.57-m) length with RJ-45/RJ-45 connectors

328 ft (100 m)

RJ-45 autosensing

Alarm relay contacts

Wire with gauge between 28-AWG and 14-AWG (0.08 and 2.08 mm2)