Replacing Alarm Relay
Wire
To connect the router to external alarm-reporting devices,
attach wires to the relay contacts on the craft interface located to the left
of the red and yellow alarm LEDs. A system condition that triggers the red
alarm LED on the craft interface also activates the upper alarm relay contact,
whereas a less serious alarm condition activates the yellow alarm LED and
lower alarm relay contact.
The alarm relay contacts accept wire
of any gauge between 28-AWG and 14-AWG (0.08 and 2.08 mm2), which is not provided. Use
the gauge of wire appropriate for the external device that you are connecting.
To replace the wires connecting to an alarm-reporting device,
follow this procedure (see Figure 50):
- Disconnect the existing wire at the external
device.
- Prepare the required length of replacement wire
with gauge between 28-AWG and 14-AWG (0.08 and 2.08 mm2).
- Use a 2.5-mm Phillips screwdriver
to loosen the small screws on the faceplate of the appropriate alarm
relay contact—the upper contact for a device that reports high
priority (red) alarms, or the lower contact for the device that reports
lower priority (yellow) alarms.
- Remove existing wires from the alarm relay contact
and insert replacement wires (the NC label on one contact
means “normally closed,” C means “common,”
and NO means “normally open”). Tighten the screws
to secure the wire.
- Attach the other end of the replacement wires to
the external device.
[