Reinstalling the FPCs

The FPCs install into the card cage at the front of the chassis, as shown in Figure 1.

Note: To help you work systematically, the following procedure directs you to reinstall FPCs starting at the top of the card cage and working down. You can install FPCs in any order, however.

Be sure there is a blank panel over every empty slot. The blank panels must be in place during router operation to guarantee adequate circulation of cooling air.

To reinstall the FPCs, follow this procedure (see Figure 36):

  1. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and connect the strap to one of the ESD points on the chassis. Verify that the router is attached to a proper earth ground. For more information about ESD, see Preventing Electrostatic Discharge Damage.
  2. Locate the slot directly below the craft interface, which is labeled FPC0, and the corresponding FPC.
  3. Verify that the ends of the ejector levers, which are located at each end of the FPC, are pushed outward, nearly perpendicular to the face of the FPC.
  4. Grasp the front of the FPC with one hand and place the other hand under the FPC to support it.

    Caution: When the FPC is out of the chassis, do not hold it by the ejector levers. They cannot support its weight.

  5. Align the rear bottom corners of the FPC with the guides at the bottom of the FPC slot. Slide the FPC into the card cage until it contacts the midplane.
  6. Push the ends of the ejector levers inward until they are nearly flush with the face of the FPC.
  7. Tighten the thumbscrew at each end of the FPC to seat the FPC securely in the chassis.
  8. Repeat the procedure for each FPC, proceeding from top to bottom through the slots.

Figure 36: Reinstalling an FPC

Image g001113.gif