All LEDs on One Supply Are Off or LED States Are not Correct
If either of the following conditions applies, perform the diagnostic
procedure described following the list of conditions:
- The LEDs on one power supply are all off, but the LEDs
on the other supply indicate that it is functioning properly.
- The LED states on one or both supplies indicate a problem:
the green LED labeled OUTPUT OK is not lit and the amber
LED labeled FAULT is lit.
Perform the following steps to diagnose and correct the problem:
- Check the red alarm LED on the craft interface:
- Replace the faulty power supply with a spare.
For instructions, see Replacing an AC Power Supply and Replacing a DC Power Supply. If the LEDs light
correctly on the spare, the original power supply is faulty. Return
it to Juniper Networks for replacement, as described in Contacting Customer Support and Returning Hardware.
- If the spare power supply also does not work, connect
the router to a different power source. You might also try replacing
the power cord (on an AC-powered router) or power cable (on a DC-powered
router). For instructions, see Replacing an AC Power Cord and Disconnecting and Connecting DC Power (you do not need
to disconnect and reconnect the grounding cable on a DC-powered router).
- If you cannot determine the cause of the problem
or need additional assistance, see Juniper Networks Technical Assistance Center.
[