[Contents] [Prev] [Next] [Report an Error]

Monitoring Services II PIC

Image g003069.gif

Software release
  • JUNOS 6.0 and later
Description
  • Passive traffic monitoring or flow collection services
  • Power requirement: 0.4 A/48 V @ 19 W
  • Monitors IPv4 packets
  • Support for collecting and exporting cflowd records

    Note: On the M40e routers and above, this PIC requires an enhanced FPC. See the hardware guide for your router for more information.

Hardware features
  • Monitors up to 400,000 packets per second
  • Support for MTUs up to 4474 bytes for SONET interfaces
Software features
  • Load distribution across multiple PICs
  • cflowd version 5 support
  • Provides start and end times of each export
  • Encapsulations:
    • High-level Data Link Control (HDLC)
    • Point-to-Point Protocol (PPP)
  • Supports firewall filtering and filter-based forwarding (FBF)

Note: Flow collection services are supported in JUNOS 6.2 and later.

Note: This PIC does not support graceful switchover. Graceful switchover can not be configured on routers that this PIC is installed in.

Cables and connectors
  • None
LEDs Status LED, one tricolor:
  • Off—PIC is offline and it is safe to remove it from the chassis.
  • Green—PIC is operating normally.
  • Amber—PIC is initializing.
  • Red—PIC has an error or failure and no further harm can be done by removing it from the chassis.

Application LED, one tricolor:
  • Off—Flow collector is not running.
  • Green—Flow collector is running under acceptable load.
  • Amber—Flow collector is overloaded.

[Contents] [Prev] [Next] [Report an Error]