Adaptive Services PIC

Image g003068.gif

Software release
  • JUNOS 6.0 and later
Description
  • Supports Network Address Translation (NAT), stateful firewall, intrusion detection services (IDS), IPSec, J-Flow accounting, tunnel services, and voice services.

    Note: Individual licenses must be purchased for these features except tunnel services, which is included with the PIC.

  • Power requirement: 0.4 A/48 V @ 19 W

Note: On the M5, M10, M20, M40, and M160 routers, this PIC requires an Enhanced FPC. See the hardware guide for your router for more information.

Hardware features
  • Throughput speeds up to 500 Mbps of unidirectional traffic or 250 Mbps of bidirectional traffic, determined by packet size
  • Active monitoring on any interface up to 250,000 packets per second
  • Support for MTUs up to 9192 bytes for Gigabit Ethernet and SONET interfaces
Software features
  • Stateful firewall with packet inspection
    • Detects SYN attacks, ICMP and UDP floods, and ping of death attacks
  • NAT for IP addresses
  • Port Address Translation (PAT) for port numbers
  • J-Flow accounting exports cflowd version 5 and version 8 records
  • Tunnel services:
    • IP-IP unicast tunneling
    • GRE unicast tunneling—supports GRE fragmentation
    • PIM sparse mode unicast tunneling
    • Virtual loopback tunnel interface for VRF table lookup
  • IPSec encryption

    Note: IPSec is supported in JUNOS release 6.1 and later.

  • Voice services:
    • Compressed Real-time Protocol (cRTP)
    • Compressed User Datagram Protocol (cUDP)

    Note: Voice services are supported in JUNOS release 6.3 and later.

  • Encapsulations:
    • High-level Data Link Control (HDLC)
    • Point-to-Point Protocol (PPP)

Note: Extended support for graceful Routing Engine switchover (GRES) has been added for this PIC. To configure GRES, you must be running JUNOS release 7.3 or later.

LEDs Status LED, one tricolor:
  • Off—PIC is offline and it is safe to remove it from the chassis.
  • Green—PIC is operating normally.
  • Amber—PIC is initializing.
  • Red—PIC has an error or failure and no further harm can be done by removing it from the chassis.

Application LED, one tricolor:
  • Off—Service is not running.
  • Green—Service is running under acceptable load.
  • Amber—Service is overloaded.