[Contents]
[Prev]
[Next]
[Index]
[Report an Error]
Replace Alarm
Relay Wires
To connect the router to external alarm-reporting devices,
attach wires to the RED ALARM and YELLOW ALARM relay
contacts on the CIP. A system condition that triggers
the red or yellow alarm LED on the craft interface also activates the corresponding
alarm relay contact.
The terminal blocks that plug into the alarm
relay contacts are supplied with the router. They accept wire of any gauge
between 24-AWG and 12-AWG (0.20 and 3.33 mm2), which is not provided. Use the gauge of
wire appropriate for the external device you are connecting.
To replace the wires connecting to an alarm-reporting device, follow
this procedure (see Figure 66:
- Disconnect the existing wire at the external device.
- Prepare the required length of replacement wire with gauge
between 24-AWG and 12-AWG (0.20 and 3.33 mm2).
- Using a 2.5 mm flat-blade screwdriver, loosen the
small screws on the face of the terminal block and remove the block from the
relay contact.
- Using the 2.5 mm flat-blade screwdriver, loosen the
small screws on the side of the terminal block. Remove existing wires from
the slots in the front of the block and insert replacement wires. Tighten
the screws to secure the wire.
-
Orient the terminal block according to the labels to the left of the
appropriate relay contact (NC means “normally closed,” C means
“common,” and NO means “normally open”).
- Plug the terminal block into the relay contact and use
a 2.5 mm flat-blade screwdriver to tighten the screws on the face of
the block.
- Attach the other end of the wires to the external device.
[Contents]
[Prev]
[Next]
[Index]
[Report an Error]