The router can have a Switching and Forwarding Module (SFM) in each of the slots labeled SFM 0 through SFM 3 at the rear of the chassis, as shown in Figure 3. To maintain the SFMs, perform the following procedures regularly:
user@host> show chassis sfm
Temp CPU Utilization (%) Memory Utilization (%) Slot State (C) Total Interrupt DRAM (MB) Heap Buffer 0 Online 41 3 0 64 19 46 1 Online 42 5 0 64 19 46 2 Online 43 4 0 64 19 46 3 Online 41 3 0 64 19 46
For more detailed output, add the detail option. The following example also specifies a slot number (1), which is optional:
user@host> show chassis sfm detail 1
Slot 1 information: State Online SPP Temperature 43 degrees C / 109 degrees F SPR Temperature 43 degrees C / 109 degrees F Total CPU DRAM 64 MB Total SSRAM 8 MB Internet Processor II Version 1, Foundry IBM, Part number 9 Start time: 2003-04-29 16:12:26 PDT Uptime: 5 days, 22 hours, 28 minutes, 26 seconds Packet scheduling mode : Disabled
For further description of the output from the commands, see the JUNOS Internet Software Operational Mode Command Reference: Protocols, Class of Service, Chassis, and Management.