J2320, J2350, and J4350 Services Routers have a fixed power supply.
J6350 Services Routers have field-replaceable AC or DC power supplies.
To connect AC or DC power:
Connect the router to earth ground with a 14 AWG
grounding cable:
Connect one end to a proper earth ground point (the rack,
for example).
Remove the screw and washer from the PEM nut on the protective
earthing terminal at the rear of the router chassis. (The J4350 and
J6350 chassis have two PEM nuts.)
Secure the other end of the cable to this grounding point
with the washer and then with the screw.
For an AC power supply only:
Insert the appliance coupler end of the power cord into
the appliance inlet on the router's power supply faceplate.
Insert the plug into an AC power source receptacle.
If the power supply includes a on/off switch, turn the
switch to on.
For a DC power supply only:
Ensure that the voltage across the DC power source cable
leads is 0 volts and that the cable leads cannot become active
during installation.
Remove the clear plastic cover protecting the terminal
block.
Remove the two center screws next to the labels –48 VDC and RTN.
Secure the positive (+) DC source power cable
lug to the RTN terminal, tightening the screw only until
snug. Do not overtighten.
Secure the negative (–) DC source power cable lug
to the –48 VDC terminal, tightening the screw only
until snug. Do not overtighten.
Replace the plastic cover.
Repeat Step Step 2 or Step Step 3 for the second
power supply, if one is installed.
For complete instructions, see the J Series Services Routers Hardware Guide.