[
Contents]
[
Prev]
[
Next]
[
Index]
[
Report an Error]
Table of Contents
- About This Guide
-
- J Series Documentation and Release Notes
- Objectives
- Audience
- Supported Routing Platforms
- Document Conventions
-
- Documentation Feedback
- Requesting
Technical Support
- Services Router Overview
-
- Overview of Services Routers
-
- J2320 Services Router Overview
- J2350 Services Router Overview
- J4350 Services Router Overview
- J6350 Services Router Overview
- J Series Services Router Hardware Features
-
- J2320 and J2350 Services Router Hardware Features
-
- J2320 and J2350 Chassis
- J2320 and J2350 Midplane
- J2320 and J2350 Routing Engine Hardware
- J2320 and J2350 Boot Devices
- J2320 and J2350 Front Panel
-
- Physical Interface
Modules (PIMs)
- Power Button and POWER
LED
- STATUS
LED
- ALARM
LED
- HA LED
- RESET CONFIG
Button
- Built-In
Gigabit Ethernet Ports
- Console Port
- AUX Port
- USB
Port
- J2320 and J2350 External Compact Flashes
- J2320 Power System
- J2350 Power System
- J2320 and J2350 Cooling System
- J4350 and J6350 Services Router Hardware Features
-
- J4350 and J6350 Chassis
- J4350 and J6350 Midplane
- J4350 and J6350 Routing Engine Hardware
- J4350 and J6350 Boot Devices
- J4350 and J6350 Front Panel
-
- Physical Interface Modules
(PIMs)
- Power Button and POWER
LED
- STATUS LED
- ALARM LED
- HA LED
- RESET CONFIG Button
- Built-In
Gigabit Ethernet Ports
- Console Port
- AUX Port
- USB Port
- J4350 Power System
- J6350 Power System
- J4350 and J6350 Cooling System
- PIM Overview
-
- PIM Terms
- Field-Replaceable PIMs
-
- J2320 and J2350 Field-Replaceable PIM and Module Summary
- J4350 and J6350 Field-Replaceable PIM Summary
- 1-Port, 6-Port, 8-Port, and 16-Port Gigabit Ethernet uPIMs
- 1-Port Gigabit Ethernet ePIMs
- Dual-Port Serial PIM
- Dual-Port T1 or E1 PIM
- Dual-Port Channelized T1/E1/ISDN PRI PIM
- T3 or E3 PIM
- Dual-Port Fast Ethernet PIM
- 4-Port Fast Ethernet ePIM
- 4-Port ISDN BRI PIMs
- ADSL PIM
- G.SHDSL PIM
- Installing a Services Router
-
- Preparing for Router Installation
-
- General Site Guidelines
- Rack Requirements
-
- Rack Size and Strength for J2320 and J2350 Routers
- Rack Size and Strength for J4350 and J6350 Routers
- Connection to Building Structure
- Router Environmental Tolerances
- Fire Safety Requirements
-
- Fire Suppression
- Fire Suppression Equipment
- Power Guidelines, Requirements, and Specifications
-
- Site Electrical Wiring Guidelines
-
- Signaling Limitations
- Radio Frequency Interference
- Electromagnetic Compatibility
- Router Power Requirements
- AC Power, Connection, and Power Cord Specifications
- DC Power, Connection, and Power Cable Specifications
- Planning for Power Management
- Network Cable Specifications
- ISDN Provisioning
- Site Preparation Checklist
- Installing and Connecting a Services Router
-
- Before You Begin
- Unpacking a J Series Services Router
- Installing J2320 and J2350 Routers
- Installing J4350 and J6350 Routers
- Connecting Interface Cables to Services Routers
- Chassis Grounding
- Connecting Power
-
- Connecting AC Power
- Connecting DC Power
- Powering a Services Router On and Off
- Establishing Basic Connectivity
-
- Basic Connectivity Terms
- Basic Connectivity Overview
-
- Router Identification
- Root Password
- Time Zone and System Time
- Network Settings
- Default Gateway
- Backup Router
- Loopback Address
- Built-In Ethernet Interface Address
- Management Access
- Before You Begin
- Connecting to a Services Router
-
- Connecting to the J-Web Interface
- Connecting to the CLI Locally
- Connecting to the CLI Remotely
-
- Configuring
the Modem at the Router End
- Connecting the Modem to the Console Port
- Connecting to the CLI at the User End
- Configuring Basic Settings with J-Web
-
- Configuring the Device’s System Identity
- Configuring the Device’s Date and Time
- Configuring Basic Settings Using the CLI Configuration Wizard
-
- About the CLI Configuration Wizard
- Using the JUNOS Software Configuration Wizard
- Configuring Basic Settings with a Configuration Editor
- Verifying Basic Connectivity and the Configuration
-
- Displaying Basic Connectivity Configurations
- Installing JUNOS Software
- Maintaining Services Router Hardware
-
- Replacing Hardware Components
-
- Tools and Parts Required
- Replacing the Console Port Cable
- Replacing a PIM
-
- Removing a PIM
- Installing a PIM
- Replacing PIM Cables
-
- Removing PIM Cables
- Installing PIM Cables
- Removing and Replacing the Chassis Cover on J2320 and J2350
Routers
- Replacing Internal Compact Flashes on J2320 and J2350 Routers
- Replacing Internal Compact Flashes on J4350 and J6350 Routers
- Replacing External Compact Flashes
- Replacing USB Storage Devices
-
- Removing the USB Storage Device
- Installing the USB Storage Device
- Replacing DRAM Modules
-
- Removing a DRAM Module
- Installing a DRAM Module
- Replacing Power System Components
-
- Replacing AC Power Supply Cords
- Removing an AC Power Supply from J6350 Routers
- Installing an AC Power Supply in J6350 Routers
- Replacing DC Power Supply Cables
- Removing a DC Power Supply
- Installing a DC Power Supply
- Replacing Crypto Accelerator Modules on J2320 and J2350 Routers
-
- Removing a J2320 or J2350 Crypto Accelerator Module
- Installing a J2320 or J2350 Crypto Accelerator Module
- Replacing Crypto Accelerator Modules on J4350 and J6350 Routers
-
- Removing a J4350 or J6350 Crypto Accelerator Module
- Installing a J4350 or J6350 Crypto Accelerator Module
- Replacing Air Filters on J2350 Routers
- Replacing Air Filters on J4350 and J6350 Routers
- Troubleshooting a Services Router
-
- Troubleshooting Hardware Components
-
- Monitoring and Correcting Chassis Alarm Conditions
- Troubleshooting Power Management
- Resetting the Configuration File When the Router Is Inaccessible
-
- Using the RESET CONFIG Button
- Changing the RESET CONFIG Button Behavior
- Recovering the Root Password
- Recovering Primary Boot Devices
-
- Why Compact Flash Recovery Might Be Necessary
- Recommended Recovery Hardware and Software
- Configuring Internal Compact Flash Recovery
- Contacting the Juniper Networks Technical Assistance Center
- Contacting Customer Support and Returning Hardware
-
- Locating Component Serial Numbers
-
- J2320 and J2350 Chassis Serial Number and Agency Labels
- J4350 and J6350 Chassis Serial Number and Agency Labels
- PIM Serial Number Label
- Power Supply Serial Number Labels
- Contacting Customer Support
-
- Information You Might Need to Supply to JTAC
- Return Procedure
- Packing a Router or Component for Shipment
-
- Tools and Parts Required
- Packing the Services Router for Shipment
- Packing Components for Shipment
- J Series Requirements
and Specifications
-
- Network Cable Specifications and Connector Pinouts
-
- Serial PIM Cable Specifications
-
- RS-232 DTE Cable Pinout
- RS-232 DCE Cable Pinout
- RS-422/449 (EIA-449) DTE Cable Pinout
- RS-422/449 (EIA-449) DCE Cable Pinout
- EIA-530A DTE Cable Pinout
- EIA-530A DCE Cable Pinout
- V.35 DTE Cable Pinout
- V.35 DCE Cable Pinout
- X.21 DTE Cable Pinout
- X.21 DCE Cable Pinout
- Fast Ethernet RJ-45 Connector Pinout
- Gigabit Ethernet uPIM RJ-45 Connector Pinout
- Gigabit Ethernet ePIM RJ-45 Connector Pinout
- Chassis Console Port Pinouts
- E1 and T1 RJ-48 Cable Pinouts
- E3 and T3 BNC Connector Pinout
- ADSL and G.SHDSL RJ-11 Connector Pinout
- ISDN RJ-45 Connector Pinout
- Safety and Regulatory Compliance Information
-
- Definition of Safety Warning Levels
- Safety Guidelines and Warnings
-
- General Safety Guidelines and Warnings
-
- Qualified Personnel
Warning
- Preventing Electrostatic
Discharge Damage
- Electrical Safety Guidelines and Warnings
-
- General Electrical
Safety Guidelines
- AC Power Electrical Safety Guidelines
-
- Power Cable Warning (Japanese)
- DC Power Electrical Safety
Guidelines
- Power Sources for Redundant Power Supplies
- DC Power Disconnection
Warning
- DC Power
Grounding Requirements and Warning
- DC Power Wiring Sequence Warning
- DC Power Wiring Terminations Warning
- Grounded Equipment Warning
- Warning Statement for Norway and Sweden
- In Case
of Electrical Accident
- Multiple Power Supplies Disconnection Warning
- Power
Disconnection Warning
- TN Power Warning
- Telecommunication Line Cord Warning
- Installation Safety Guidelines and Warnings
-
- Chassis Lifting Guidelines
- Installation Instructions Warning
- Rack-Mounting Requirements
and Warnings
- Ramp Warning
- Laser and LED Safety Guidelines and Warnings
-
- General Laser Safety Guidelines
- Class 1
Laser Product Warning
- Class 1 LED Product
Warning
- Laser Beam Warning
- Radiation from
Open Port Apertures Warning
- Maintenance and Operational Safety Guidelines and Warnings
-
- Battery Handling Warning
- Jewelry Removal
Warning
- Lightning
Activity Warning
- Operating
Temperature Warning
- Product Disposal
Warning
- Agency Approvals
- Compliance Statements for Environmental Requirements
-
- Lithium Battery
- Compliance Statements for EMC Requirements
-
- Canada
- European Community
- Japan
- United States
-
- FCC Part 15 Statement
- FCC Part 68 Statement
- Index
-
- Index
[
Contents]
[
Prev]
[
Next]
[
Index]
[
Report an Error]