Verifying the State of the Links in the Routing Matrix
Purpose
After the T1600 router has booted, verify the state of the links in the routing matrix.
Action
- Verify the state of the optical switch fabric
links by issuing the show chassis fabric plane extensive command.
Verify that the state of each optical link is Links ok.
user@host> show chassis fabric plane extensivesfc0-re0: -------------------------------------------------------------------------- Fabric Management PLANE State: PLANE 0: Spare ABS-SIB-F13 0 : Spare ABS-SIB-F13 1 : Spare ABS-SIB-F2 0/0 : Spare ABS-SIB-F2 0/2 : Spare ABS-SIB-F2 0/4 : Spare ABS-SIB-F2 0/6 : Spare ABS-SIB-F13 0 Even: LCC 0, ST-SIB-L 0 : Links ok SG 0 Port 0 : Links ok Port 1 : Links ok Port 2 : Links ok Port 3 : Links ok SG 1 Port 0 : Links ok Port 1 : Links ok Port 2 : Links ok Port 3 : Links ok SG 2 Port 0 : Links ok Port 1 : Links ok Port 2 : Links ok Port 3 : Links ok SG 3 Port 0 : Links ok Port 1 : Links ok Port 2 : Links ok Port 3 : Links ok ABS-SIB-F13 0 Odd: LCC 1, ST-SIB-L 0 : Links ok SG 0 Port 0 : Links ok Port 1 : Links ok Port 2 : Links ok Port 3 : Links ok SG 1 Port 0 : Links ok Port 1 : Links ok Port 2 : Links ok Port 3 : Links ok SG 2 Port 0 : Links ok Port 1 : Links ok Port 2 : Links ok Port 3 : Links ok SG 3 Port 0 : Links ok Port 1 : Links ok Port 2 : Links ok Port 3 : Links ok ABS-SIB-F2 0/0: Links ok ABS-SIB-F2 0/2: Links ok ABS-SIB-F2 0/4: Links ok ABS-SIB-F2 0/6: Links ok ABS-SIB-F13 1 Even: LCC 2, ST-SIB-L 0 : Links ok SG 0 Port 0 : Links ok Port 1 : Links ok Port 2 : Links ok Port 3 : Links ok SG 1 Port 0 : Links ok Port 1 : Links ok Port 2 : Links ok Port 3 : Links ok SG 2 Port 0 : Links ok Port 1 : Links ok Port 2 : Links ok Port 3 : Links ok SG 3 Port 0 : Links ok Port 1 : Links ok Port 2 : Links ok Port 3 : Links ok ABS-SIB-F13 1 Odd: LCC 3, ST-SIB-L 0 : Links ok SG 0 Port 0 : Links ok Port 1 : Links ok Port 2 : Links ok Port 3 : Links ok SG 1 Port 0 : Links ok Port 1 : Links ok Port 2 : Links ok Port 3 : Links ok SG 2 Port 0 : Links ok Port 1 : Links ok Port 2 : Links ok Port 3 : Links ok SG 3 Port 0 : Links ok Port 1 : Links ok Port 2 : Links ok Port 3 : Links ok ABS-SIB-F2 0/0: Links ok ABS-SIB-F2 0/2: Links ok ABS-SIB-F2 0/4: Links ok ABS-SIB-F2 0/6: Links ok PLANE 1: Online ABS-SIB-F13 3 : Online ABS-SIB-F13 4 : Online ABS-SIB-F2 1/0 : Online ABS-SIB-F2 1/2 : Online ABS-SIB-F2 1/4 : Online ABS-SIB-F2 1/6 : Online ABS-SIB-F13 3 Even: LCC 0, ST-SIB-L 1 : Links ok SG 0 Port 0 : Links ok Port 1 : Links ok Port 2 : Links ok Port 3 : Links ok SG 1 Port 0 : Links ok Port 1 : Links ok Port 2 : Links ok Port 3 : Links ok SG 2 Port 0 : Links ok Port 1 : Links ok Port 2 : Links ok Port 3 : Links ok SG 3 Port 0 : Links ok ... - Verify the state of the electrical switch fabric
links by issuing the show chassis fabric topology sfc 0 command.
Verify that the state of each electrical link is OK.
user@host> show chassis fabric plane topology sfc 0sfc0-re0: -------------------------------------------------------------------------- SIB:0 ===== Out-Links: ========= SFC0_F13_SIB_36 -> LCC00_ST_SIB_L00 Status ==================================================================== SF_3_00_FB_D(04,11) -> FPC0_T_SG(0,0,0)_FB_D(04,11) OK SF_3_00_FB_D(04,10) -> FPC0_T_SG(0,0,1)_FB_D(04,10) OK SF_3_00_FB_D(04,09) -> FPC0_T_SG(0,0,2)_FB_D(04,09) OK SF_3_00_FB_D(04,08) -> FPC0_T_SG(0,0,3)_FB_D(04,08) OK SF_3_00_FB_D(04,07) -> FPC0_T_SG(0,0,4)_FB_D(04,07) OK SF_3_00_FB_D(04,06) -> FPC0_T_SG(0,0,5)_FB_D(04,06) OK SF_3_00_FB_D(04,05) -> FPC0_T_SG(0,0,6)_FB_D(04,05) OK SF_3_00_FB_D(04,04) -> FPC0_T_SG(0,0,7)_FB_D(04,04) OK SF_3_01_FB_B(16,11) -> FPC4_T_SG(2,0,0)_FB_B(16,11) OK SF_3_01_FB_B(16,10) -> FPC4_T_SG(2,0,1)_FB_B(16,10) OK SF_3_01_FB_B(16,09) -> FPC4_T_SG(2,0,2)_FB_B(16,09) OK SF_3_01_FB_B(16,08) -> FPC4_T_SG(2,0,3)_FB_B(16,08) OK SF_3_01_FB_B(16,07) -> FPC4_T_SG(2,0,4)_FB_B(16,07) OK SF_3_01_FB_B(16,06) -> FPC4_T_SG(2,0,5)_FB_B(16,06) OK SF_3_01_FB_B(16,05) -> FPC4_T_SG(2,0,6)_FB_B(16,05) OK SF_3_01_FB_B(16,04) -> FPC4_T_SG(2,0,7)_FB_B(16,04) OK SF_3_02_FB_D(05,08) -> FPC1_T_SG(0,2,0)_FB_D(05,08) OK SF_3_02_FB_D(05,07) -> FPC1_T_SG(0,2,1)_FB_D(05,07) OK SF_3_02_FB_D(05,06) -> FPC1_T_SG(0,2,2)_FB_D(05,06) OK SF_3_02_FB_D(05,05) -> FPC1_T_SG(0,2,3)_FB_D(05,05) OK SF_3_02_FB_D(05,03) -> FPC1_T_SG(0,2,4)_FB_D(05,03) OK SF_3_02_FB_D(05,02) -> FPC1_T_SG(0,2,5)_FB_D(05,02) OK SF_3_02_FB_D(05,01) -> FPC1_T_SG(0,2,6)_FB_D(05,01) OK SF_3_02_FB_D(05,00) -> FPC1_T_SG(0,2,7)_FB_D(05,00) OK SF_3_03_FB_B(17,08) -> FPC5_T_SG(2,2,0)_FB_B(17,08) OK SF_3_03_FB_B(17,07) -> FPC5_T_SG(2,2,1)_FB_B(17,07) OK SF_3_03_FB_B(17,06) -> FPC5_T_SG(2,2,2)_FB_B(17,06) OK SF_3_03_FB_B(17,05) -> FPC5_T_SG(2,2,3)_FB_B(17,05) OK ... In-Links: ========== LCC00_ST_SIB_L00 -> SFC0_F13_SIB_36 Status ==================================================================== FPC0_T_SG(0,0,0)_FB_D(01,11) -> SF_1_00_FB_D(01,11) OK FPC0_T_SG(0,0,1)_FB_D(01,10) -> SF_1_00_FB_D(01,10) OK FPC0_T_SG(0,0,2)_FB_D(01,09) -> SF_1_00_FB_D(01,09) OK FPC0_T_SG(0,0,3)_FB_D(01,08) -> SF_1_00_FB_D(01,08) OK FPC0_T_SG(0,0,4)_FB_D(01,07) -> SF_1_00_FB_D(01,07) OK FPC0_T_SG(0,0,5)_FB_D(01,06) -> SF_1_00_FB_D(01,06) OK FPC0_T_SG(0,0,6)_FB_D(01,05) -> SF_1_00_FB_D(01,05) OK FPC0_T_SG(0,0,7)_FB_D(01,04) -> SF_1_00_FB_D(01,04) OK FPC4_T_SG(2,0,0)_FB_B(13,11) -> SF_1_01_FB_B(13,11) OK FPC4_T_SG(2,0,1)_FB_B(13,10) -> SF_1_01_FB_B(13,10) OK FPC4_T_SG(2,0,2)_FB_B(13,09) -> SF_1_01_FB_B(13,09) OK FPC4_T_SG(2,0,3)_FB_B(13,08) -> SF_1_01_FB_B(13,08) OK FPC4_T_SG(2,0,4)_FB_B(13,07) -> SF_1_01_FB_B(13,07) OK FPC4_T_SG(2,0,5)_FB_B(13,06) -> SF_1_01_FB_B(13,06) OK FPC4_T_SG(2,0,6)_FB_B(13,05) -> SF_1_01_FB_B(13,05) OK FPC4_T_SG(2,0,7)_FB_B(13,04) -> SF_1_01_FB_B(13,04) OK FPC1_T_SG(0,2,0)_FB_D(02,08) -> SF_1_02_FB_D(02,08) OK FPC1_T_SG(0,2,1)_FB_D(02,07) -> SF_1_02_FB_D(02,07) OK FPC1_T_SG(0,2,2)_FB_D(02,06) -> SF_1_02_FB_D(02,06) OK FPC1_T_SG(0,2,3)_FB_D(02,05) -> SF_1_02_FB_D(02,05) OK ...
- If the state of all links is correct, the connections between the TXP-F13 SIBs and the TXP-T1600 SIBs are operating correctly.
- If the state of any optical link is not Links ok, or the state of any electrical link is not OK, see Troubleshooting the Switching Planes in the Routing Matrix, or contact your customer support representative for additional instructions.