Technical Documentation

Maintaining the T1600 Host Subsystem

The host subsystem comprises a Routing Engine and up to two adjacent control boards functioning together.

To maintain the host subsystem, check the host subsystem LEDs (HOST0 and HOST1) on the craft interface. If the red HOST0 FAIL or HOST1 FAIL LED is lit, look at the LCD to get more information about the cause of the problem. For more information about the LEDs and the display, see T1600 Craft Interface Description

To maintain the Routing Engines and control boards:

Maintaining the T1600 Routing Engines

Purpose

For optimum router performance, verify the condition of the routing engines and the control boards.

Action

On a regular basis:

  • Check the host subsystem LEDs on the craft interface. For more information about the LEDs and the display, see T1600 Craft Interface Description.
  • Check the LCD on the craft interface to view information about the router temperature and the status of the Routing Engines.
  • Issue the show chassis routing-engine command to check the status of the Routing Engines. The output is similar to the following:

    user@host> show chassis routing-engine
    Routing Engine status:
      Slot 0: 
      Current state             Master 
      Election priority         Master (default) 
      Temperature            34 degrees C / 93 degrees F
        DRAM               2048 Mbytes
        CPU utilization: 
        User                  0 percent 
        Background            0 percent 
        Kernel                1 percent 
        Interrupt             0 percent 
        Idle                 99 percent 
        Start time              2002-01-22 05:21:31 UTC
        Uptime                  10 days, 16 hours, 4 minutes, 52 seconds
        Load averages:          1 minute   5 minute  15 minute
                                    0.00       0.00       0.00
    Routing Engine status:
      Slot 1: 
      Current state             Empty
    

For further description of the output from the commands, see the Junos System Basics and Services Command Reference.

Maintaining the T1600 Control Boards

Purpose

For optimum router performance, verify the condition of the control boards.

Action

On a regular basis:

  • Check the LEDs on the control board faceplate.
  • Issue the show chassis environment cb command to check the status of the T-CBs. The output is similar to the following:

    user@host> show chassis environment cb
    CB 0 status:
      State                           Online Master
      Temperature                  29 degrees C / 84 degrees F
      Power:
        1.8 V                    1809 mV
        2.5 V                    2496 mV
        3.3 V                    3295 mV
        4.6 V                    4687 mV
        5.0 V                    5042 mV
        12.0 V                  11985 mV
        3.3 V bias               3277 mV
        8.0 V bias               7472 mV
      GBUS Revision                40
      FPGA Revision                 7
    
    

For further description of the output from the commands, see the Junos System Basics and Services Command Reference.


Published: 2010-08-11

|
|